My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8630 EVERGREEN WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
8630
>
BASE FILE
>
8630 EVERGREEN WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2018 8:13:38 AM
Creation date
2/10/2017 1:19:44 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8630
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � ' <br /> .PUBL/C f�f/OrrXS <br /> March 11, 1999 <br /> Bob MacMillan '`b ' <br /> Sound Ventures �� � �` '��� - �' � � ° <br /> - . ,.. , , . „ ... <br /> 320 106th NE, Suite 100 ,, � , ` � r • <br /> Bellewe, W.4 98004 � � <br /> Subjecr. Projecr. Sound Ventures " '� � �• '` <br /> Job Address: Parcel C, Evergreen Way F =, ,� <br /> Plan Check No.: 61547 "' `"' <br /> Dear Mr. MacMi!lan: <br /> In response to your application for a construction permit, your plans have been examined and you are I, <br /> advised that the issuance of a permit is being withheld for the reasons listed below. These comments <br /> address building issues only, additional revisions or additions may be required by other departments <br /> (such as Utilities, Planning or Fire). All references refer m the 1997 Uniforrc Building Code, as <br /> amended by the State of Washington and/or Washington State Energy Code 1997 Edition, unless stated <br /> otherwise. <br /> In order for the processin� of xour application to continue, it will be necessary to <br /> provide the Buildmg Division with two complete new sets of drawings ref7ecting the <br /> corrections requestecl. <br /> 1. The drawings should indicate the requirement for safety glass in hazardous !ocations per UBC <br /> 2406. <br /> 2. Please provide verification that the connections of details H & L/S4 comply with the <br /> anchorage requirements of UBC 1G33.2.8.1. <br /> 3. Please designate make and model of the connectors in detail H/S4 and provide current <br /> evidence of approval by ICBO for seismic loading, , <br /> 4. Please add the connectors (item 3) to the lis[ of items to be inspected by an approved testing <br /> lab in accordance with UBC 1701. <br /> 5. Please provide connection details for the parapet bracing. <br /> Prepare a response letter showing where each item in this currection letter is addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals s�ali be of sufficient detail and contain sufficient informa[ion to ensure diat thc <br /> proposed structure will be constructed in compliance with all adopted codes. <br /> Sircerely, �J,�; °�� <br /> S[eve Miller, PE <br /> Associate Engineer <br /> sM:i�aSn�PmkJ1 <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 90201 • (425)257-8800 • Fax(425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.