Laserfiche WebLink
April 20, 2007 <br />N�GINEfRING / PUBLIC SERVICES DEPARTMENT <br />Mr. �mest Scott <br />12320 Sth Avenue NL <br />Seatde, WA )8125 <br />Project: <br />Job Address: <br />Plan Review No: <br />Changc of usc: SFR to Office <br />9308 Lvcrgrccn Way <br />C0702-037 <br />R�: Corrections Lcucr <br />Dear Mc Scott, <br />In response to your application for building cou::truction permit, the plans have Ueen examined and you are <br />advised that a permit rcview cannot be completed unti! thc following issues are resolved. In order for the <br />processing of your application to continue, it will be nccessary to provide the Building Division with t«'o full <br />sets of drawings reflecting the information requested. <br />Building Pcrmit SuUmEttal: <br />L'Che following requirements are Gom the City of �verett Constnmtion Permit Checklist for New <br />Commercial Projects. The site should indicate the separation distance (dimensioned) of the hvo <br />�� buildings Gom each other, the (loor area of each building, the primary occupancy and any incidental <br />use or accessory occupancies, and the type of construction for each Uuilding. CuRent applicable <br />building codes should be indicatcd in the code analysis for new work ender this permit. <br />2. fixisling grade nnd revisions to ex�sting grade should be shown un the site plan and on the Iloor <br />plans. The location of grade should be indicated at the perirt:eter of the lowest floor in clevation, <br />✓ plan and section on thc plans .nd elevations submittcd ttmt meet the required minimum scale <br />requirements. <br />✓ 3. Per the Ciry of Everett Conslruction Pcrmit Checklist for New Commercial Projects: building plans <br />should be submilted at I/8" = 1'-0' minimum scale; a Luilding seclion is required; new stair and <br />ramp pians slioulJ be indicated at'/d'=1'-0" minimum sc2.le; uew toilet room plans and elevations <br />should be submitted at'/d'=1'-0" minimum scale. Det�il references and schedules far new partitions, <br />ramps, windows, doors, fixtures, service caunters or fised clements ovcr 5'-9", are nlso required per <br />IBC 105.2 and the City of Lverett Construction Pe;miT Checklist }'r.r New Commercial Projects. <br />% d. Any new work on the side of Qie building lhat is adjacent to the cxisting veterinary clinic may <br />require fire resistance ratings, based on the distance of separation, �vhich should be dimensioned <br />clearly on thc dra�vings. <br />�� 5. Thc extent of the building revisions should bc indicated graphiwlly ;typically darker) on the plans to <br />include stairs, ramps, waps, fixtures, and doors to indicate Aic scope of new work. Existing work to <br />remain should be indicated graphically (typically in halftone) to distinguish the existing from the <br />new work, so that somcone not famili. r with the plans could build �t. <br />CI7Y OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />ti:U1I lulcy\Word\C0702-077 930X IA�crErccn',P�y.aoc <br />I/� <br />