Chepler A. Accessible Routes <br />404.2.7 Closing Speed. <br />404.2.7.1 Door Closers. Door closers shell <br />be adjusted so thet irom an open positlon of <br />90 degrees, the time required to move ihe <br />door to an open position of 12 degrees shall <br />be 5 seconds minimum. <br />404.2.7.2 Spring Hinges. Door spring <br />hinges shell be adjusted so ihal irom the <br />open position of 70 degrees, ihe door shell <br />move to the closed position in 1.5 seconds <br />minimum. <br />404.2.8 Door-Opening Force. Flre doors shall <br />have the minimum opening force allo�vable by <br />the approprfale administrative authority. Tha <br />forco for pushing or pulling open doors other <br />than fire doors shall be as follows: <br />1. Interior hfnged door: 5.0 pounds (22.2 N) <br />meximum <br />2. Sliding or tolding door: 5,0 pounds (22.2 <br />N) maximum <br />These iorces do not epply to ths torco required <br />to retract letch bolts or disengage olher devices <br />that hold the door in a closed posilion. <br />404.2.9 Door Surface. Door surfacos wi�hin 10 <br />inches (255 mm) oithe iloor, measured verlical- <br />ly, shall be e smooth surface on lhe push side <br />extending the full width of the door. Paris creat- <br />ing horizontal or vertical Jofnts in such surface <br />shell be within �/16 (nch (1.6 mm) oi tha same <br />plane as ihe other. Cavities created by added <br />kick plates shall be capped. <br />EXCEPTiONS: <br />1. Sliding doors. <br />2. Tempered gless doors wilhout stiles and <br />having a bottom rail or shoe with the top <br />leading edge iepered at no less than 60 <br />degrees irom the horizontel shall not be <br />required to meet tne 10 inch (255 mm) <br />bottom rail height requiremen!. <br />3. Doors that do not extend to within 10 <br />inches (255 mm) of the iloor. <br />A04.2.10 Vlsion Lites. Doors and sidelites ad- <br />jacent 10 doors con;aining one or more glezing <br />panels ihat permit viewing through the panels <br />shall havo ihe bottom of at least one panel on <br />either ihe door or an adjacent sidelite 431nches <br />(1090 mm) meximum above the iloor. <br />EXCEPTION: Vislon lites with the lowest <br />part more than 66 inches (1675 mm) ebove <br />ICC/ANSI A117.1-20D3 <br />the iloor are not required to comply with <br />Section 404.2.10. <br />404.3 Automatic Doors. Automatic doors and au- <br />tomaiic gates shall comply witli Section 404.3. Full <br />powered automaiic doors shell comply with ANSI/ <br />BHMA A156.10 Iisted in Section 105.2.4. Power- <br />essist ond low-energy doors shell comply with <br />ANSI/BHMA A156.19 listed in Section 105.2.3. <br />EXCEPTION: Doors, doorways, and gates de- <br />signed to be operated only by security personnel <br />shall not be required to comply with Sections <br />404.3.2, 404.3.4, and 404.3.5. <br />404.3.1 Clear Opening Wldth. Doonvays shall <br />have a clear opening widih of 32 inches (815 <br />mm) in power-on and power•off mode. The <br />minfmum clear opening width for automatic <br />door systems shell be based on the cleer <br />opening width provided with all leafs in tha open <br />positfon. <br />404.3.2 Maneuvering Clearances. Maneuver- <br />ing clearances at power-assisted doors shall <br />comply with Sectian 404.2.3. <br />404.3.3 Thresholds. Thresholds and changes <br />in level at doorways shall comply with Sectlon <br />404.2.4. <br />404.3.4 Two Doors in Serles. Doors In series <br />shell comply with Section 404.2.5. <br />404.3.5 Control Switches. Manually operated <br />controi switches shall comply with Seclion 309. <br />The clear iloor space adJacent to the control <br />switch shall 6e located beyond ihe erc oi the <br />door swing. <br />405 Ramps <br />405.1 General. aamps alorg accessible routes <br />shell comply wilh Seclion 405. <br />405.2 Slope. Ramp runs shall have e running slope <br />not steeper than 1:12. <br />EXCEPTION: In exisiing buildings or facilities, <br />remps shall be permitter! to have slopes steeper <br />than 1:12 complying witn Table 405.2 where such <br />slopes aro necessary due tu spece limitafions. <br />405.3 Cross Slope. Cross slope of ramp runs shall <br />not be steeper ihan 1:48. <br />405.4 Floor Surfaces, Floor surtaces of ramp runs <br />shall comply wiih Section 302. <br />