My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9605 EVERGREEN WAY PACIFIC NORTHWEST IMPORTS 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
9605
>
PACIFIC NORTHWEST IMPORTS
>
9605 EVERGREEN WAY PACIFIC NORTHWEST IMPORTS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2022 8:20:23 AM
Creation date
2/10/2017 2:32:19 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9605
Tenant Name
PACIFIC NORTHWEST IMPORTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M. Additional information for Type I hood only: <br />1. Grease filters shall be installed at minimum 45 degree angle <br />and equipped with drip tray and gutter beneath lower edge of filters. Proposed degrees. <br />2 Distance between lowest edge of grease filters and cooking surface of: y <br />Grill, fryer, exposed flame shall be not less than 2 ft. Propnsed <br />Exposed charcoal, charbroil shall be not less than 3-1/2 ft. Proposed <br />3 Type I hood and duct shall have clearances from combustible construction of: <br />PROTECTED <br />UNPROTECTED with 1-Hour Fire -Rated Material <br />Hood Min. Req. 18 in. Proposed in. Min. Req. 3 in. Proposed _.�— in. <br />Duct Min. Req. 18 in. Proposed in. Min. Req. 3 in. Proposed 3_ in. <br />4. Hoods less than 12 inches from ceilings or walls shall be flashed solidly. <br />Flashing provided [:1 Yes L"J No Distance from ceiling i _ in., wall _ in. <br />5. All joints and seams shall be made with continuous liquid -tight weld or braze n+de on the external <br />surface of the duct system. Vibration insulation connector may be used provided it consists of noncom- <br />bustible packing in a metal sleeve joint. <br />6. Centrifugal fans used for discharging grease exhaust shall be positioned in a bottom horizontal <br />discharge position only. A duct that diverts the fan discharge shall not exceed 3 times the diameter of <br />the fan outlets connected to the fan outlet. The duct shall be provided with an adequate drain opening <br />at the lowest point to permit drainage of grease to a suitable collection device. <br />7. Fire extinguishers Shop drawings shall be submitted to DCLU for Fire Department approval prior to field <br />installation. <br />References <br />1) Seattle Mechanical Code 1997 <br />2) Director's Rule 5-96 <br />3) Seattle Building Code 1997 <br />Sheet 4 <br />