Laserfiche WebLink
• Plan Ct�eck No. B 57831 � 4�" <br />March l6, 1998 <br />Page 2 of 2 <br />,� ��� � ,6, v <br />�� �� '� erflow drains should be provided for the storage building. Note tLat an overtlow scupper <br />t of thc westem wall will not be permitted due to opeuing protection r.xluired. Secdon <br />1506.3 ��-,� l L 7��� O <br />Conveaimce store <br />��/(�/��Sattery backup or emerge�y power should be provided for :he exit signs. Section 1013.4 <br />Y <br />�� T . Details should be submitted for laural bracing with compression struts for tre suspended <br />ceiling. UBC Standard 25-2, Table 25-A, Foomote 1. �� D <br />u n C� e slab-on-grade insulation should be installed between the edge of the slab and the stem <br />I] �-" wall as the 15/t felt specified dces not provide an adequate thermal break. Secdon 1311.5 <br />�' � ci'� a f� C) ��+ S�i�,v� <br />� r� 7— oof insutauon should be specified to be a minunum of R-21. Section 1322 f <br />� �t.0 <br />!� Calculadons should be provided showing that the interior and exterior lighting proposed aze <br />within the power allowances per Section 1520. <br />?�`. <br />� l� �� i E�curior lighting not intended for 24-hour r.onturuous use should be shown with automatic <br />controls to tum the lighu off during daylight t:ours. Section 1513.5 <br />� �� � �� <br />p �, i��. 'he accessible parking space should be shown as having a sign 3'-5' gh centered at the head <br />f the space and bearing the words, "State Disabled Pazking Pc : Required". Section <br />_ 1107.3 p �, p <br />�./ T A l, D <br />���—�w e maicitfium slope for the curb ramp, both sides and front, should be shown as 1:12 as the <br />idth of sidewalk at the top of the ramp is less than 48". Secdon 1106.4.73 At', � <br />i�'� <br />�� yi � e door from the Hall into the storage room, labeled E/3, should pivot on the opposite hinge <br />o maintain 18" clear on the latch side from the approach direction. Section 1106.10.3 <br />.. � � , �.,�� �d�-� <br />Prepaze a responce letter showin where each item in this correction letter is addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information !o ensure that die <br />proposed structure will be constructed in compliance with all adopted codes. <br />Since:ely, <br />/� //.�% <br />:-/�� �-- <br />ny L.ee <br />Associate Engineer <br />