Laserfiche WebLink
'NGINEERING / PUBUC SERV/CES DEPARTMENT <br />May 4, 2006 �(� (�i' 7����v �' P« �V <br />�r. Mohscni Ranchcs <br />Q 07 NW SGth Strcet <br />SeSttic. WA 98107 <br />Projccl: Dcpat1mcnt of Rcvcnuc 7'cuant Improvemcnt <br />JoU Adacess: 9930 Cvcrgrcen \�Vay, I3uilding I3 <br />Plan P.ev�w No: B0G04-004 <br />Dear Mr. <br />13uilding perniit 130G04-UCa, issucd on Aprii 27, 200G, is immrdiately and cflcctivcly revised by this Iciter to <br />reticct the follo�ving conditions to the permit that requirc additional modifications to the pem»t documents. <br />As part af tl�e condiflons to this permit, we will rcquire bvo sets of the revised drawings, re0ecting the <br />following correctiuns, whic6 will then be issucd to modify the permit sets on file in our office and on-site. <br />Construction: <br />1. Thc removed cxisting tenant demising wall (a hvo hour arca separation wall) should'�c repiaced with a <br />ncw hvo hour area separation wall as the tenant demising wall, per thc Uniform Bwiding Code-1997 <br />(UI3G97), Scction �0G.4.2. <br />2. The tcnant improvemcnt area has Uccn incrcased from the original 1950 Uuilding shell configuration oP <br />tcnant areas. In addition to thc new tcnant demising wall required in Item 1 above, another pvo hour <br />arca separation wall will be mquircd to ro-cstahiish the original tenant improvement area of <br />approximatcly SS92 syuarc fect, or th�s tenant improvemcnt arca will bc required to bc sprinklcrcd to <br />NPPA-13 specifications, per the City of�Everett Sprinkler Ordinanee (1902-92, Scetion 1 G.7(.030). <br />3. Openings (including doors and windows) in the arca separation u�alls should bc protcctcd by 90 <br />minute firc-resistancc rated assemblies, per UBC-97 Section 506.4.2. <br />4. All duct penctrations tivough the hvo hour area separation ���alls should have combination smoke and <br />firc dampers per UBC-97 Scctions 713.10 and 713.11. <br />Upon suUmission of the rcvised drawings, your applicacion will be given priority and plan review will begin. <br />All requircd submittals ntust be of sufficient detail and information to ensure that the proposed structure will <br />be constructed in compliance with all referenced codes. If you would like to discuss this tetter, please contact <br />me at 425-257-8813. <br />; M. I I iley <br />is Lxa iiner <br />C� dy 'ap�5 CQ nnell Desi �n; Tc� `udden, Chief Building Inspector; Tony Lee, Permit 3e`rvices Manager <br />V S y � f (),pp� <br />CI OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />9930 Gvcrgrocn ��'oy. �luildine Il.dnc <br />