My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9930 EVERGREEN WAY GSA 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
9930
>
GSA
>
9930 EVERGREEN WAY GSA 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2020 7:57:30 AM
Creation date
2/10/2017 3:00:26 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9930
Tenant Name
GSA
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 28, 2011 <br />PUBL/C M/O/�K5 <br />Ms. Jessica Rchinson <br />Crown Fire Prot�a�un, Inc. <br />PO Box 12113 <br />Mill Creek, WA 98082 <br />Project: SPRINKLER-T.I. FOR GSA <br />Job Address: 9930 EVERGREEN WAY #116 <br />Plan Review No: K1106-006 <br />Dear Ms. Robinson, <br />In response tu your application for a new suppression construction permit, the plans have been examined <br />and you are advised that this is an incomplete submiltal, and the permit review cannot be resumed until <br />the following issues are resolved. <br />1. Civil drawings should be submitted for a Public Works permit for tlie new work to connect to the <br />main "by others". Please contact Mike Ward, Maintenance and Operations for Supervisor, (425-257- <br />8827) for a preliminary estimate and scope of work for the tap and connection to the main, and <br />possibly for the new vault for the double check detector assembly. <br />2. The sprinkler drawings submitted for 168 new heads are missing the caiculations and the cut for the <br />double check detector assembly for che vauit. <br />3. The location of the post or wall indicator valve (PIV or WIV), check valve, and the fire department <br />connection (FDC) should be shown on the sprinkler plans. <br />Upon submission of three sets of revised drawings, DCDA catalog cut, and caiculations reFlecting <br />the corrections requested, the review of this application will be resumed. Applicable codes include the 2009 <br />Intern�;ional Building Code (IRC), the 2009 International Fire Code (IFC), and referenced standards. All <br />codes, as adopted by the City of Everett Municipal Code, should include current revisions by the State of <br />Washington. <br />These comments address building issues only. Revisions or additions may be required by other <br />departments (such as Utilities, Planning or Fire). All required submittals must be of sufficient detail and <br />information to ensure that the proposed structure will be constructed in compliance with ali adopted codes. <br />You can reach me directly to discuss this letter by e-mail at mhalevC�a ci.everett.wa.us or by phone at 425- <br />257-8813. <br />Plans Examiner <br />Cc: k Bro s, Tony Lee, Gordon Witcher, Mike Ward, Jim Venturo, Ted [iudden, Tim Markham <br />Ke eller, Davis Schueller General Contractors <br />EN �IIJEERING I PUBLIC SERVICES DIVISION • 3200 Cedar Street • Everett, WA98201 •(425) 257-8fj00 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.