Laserfiche WebLink
� <br />7 <br />f.'_.a�.a .._..__._ .. _... r^i <br />! - • � . <br />,� 6. Detailed draai,ngei. �a accordance rrith City Des_„� and Conatruction <br />Standards ehall be submitted to the Public Worka Departmmt ahowing <br />site parking laqout, landecaping, utilitiea, storm drainage, temporarq <br />construction eroaion aontrol, and all required improvements in the <br />public right-of-raq. Public Norks Dapartment approval of theae <br />draeiage is required prior to any permita being iseued. A11 <br />improvements shall be completed, approved and warraated before the <br />Occupancy Permit ia iasued. (SEPA Public Servicea Policiea) <br />' `, 7. <br />< <br />• ✓ 8. <br />�,�t standard alley improvementa are reqcired to the alley frontage ou <br />the north property line to Wall Street. (SEPA Public Services Policiea) <br />G�rb, gutter •and aidewalk on the propoeal's full frontage of Federal <br />Avenue muet be replaced. (SEPA Public Servicea Policies) <br />9. Special charges for connection to aexer system in accordance with <br />Ordiasnce 984-83 are applicable. The actual coat ahall be computed by <br />the Building Diviaion per the ordiaance ia effect at the time and <br />according to the laformation provided on the approved plans on the date <br />of permit issuance. <br />� 10. <br />Oa-site detention <br />detention, payment <br />Servicea Yoliciea) <br />is required, or in lieu of providing on-site <br />to City Drainage Fund 340 ia alloxed. (SEPA Public <br />11. Any grading/fill on thia site ahall be done so as to not impact the <br />surrnunding propertiea. (SEPA Farth Policiea) �_,� �/^ 2� <br />f�y <br />12. Fire flow requirementa must be a minimum of 2100 GM4' (SEPA Public <br />Services Policiea) --=�--- <br />13. An automatic fire alarm syatem is required. This system muat camply <br />rrtth U.P.C. standarda 10-2-85 editioa. (SEPA Public Services Policies) <br />Bas�mt eprinklers may be required, dependiag oa the number of <br />openings in the propoaed building. (SEPA Public Servicea Policiea) <br />The applicant muet provide portable fire protection on ali levels; the <br />minimum required ia: <br />a. <br />b <br />lA lOBC in each apartment and two (2) 2A lOBC ia basemeat. <br />(Certificatioa letter to Fire Dept. ie required annually) or <br />2A lOBC within 75 feet of travel oa all levels <br />A legible street addresa ie required for the apartment complex; also, <br />each apartment unit must have an I.D. number. (SEPA Public Services <br />Policies) <br />The pr�poaed dumpater may aot be any closer than 5 feet from <br />combuatible walls or eave lines. (SEPA Public Services Policies) <br />-2- <br />