My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3611 FEDERAL AVE 2018-01-02 MF Import
>
Address Records
>
FEDERAL AVE
>
3611
>
3611 FEDERAL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2022 2:23:54 PM
Creation date
2/10/2017 4:07:52 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3611
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />Brian & Kathleen Jones <br />October 30, 1998 <br />Plan Check #60171 <br />Page 2 of 3 <br />/14: Specify approved weatherproof material at decks and balconies. Pressure treated wood or cedar <br />is acceptable. <br />Provide full height cross-section through the building showing framing, interior/exterior <br />sheathing, plate heights, insulation, foundation, finished grade, etc. <br />Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, <br />water closet compartments, laundry rooms and similar rooms. The point of discharge of exhaust <br />air shall be at least 3' from any opening in the building. <br />Provide smoke detector(s) in each bedroom and in the corridor or area giving access to each <br />/ separate sleeping area. Detectors shall be installed on each floor and in basements. <br />Show location of 22" x 30" attic access with 30" minimum headroom. <br />J6' Show how dwelling is provided with comfort heating facilities capable of maintaining a room <br />te•-rperature of 70 degrees F at a point 3 feet above the floor in all habitable rooms. <br />_,7. Provide tempered glass at required hazardous locations. Show on plan view and window <br />schedule. <br />y8!Provide 36" high protective guardrail for decks, porches, balconies, raised floors (more than 30" <br />above grade or floor below), and open sides of stair landings. Guardrail openings shall be less <br />than 4". <br />Provide detail of attic ventilation type, size, and location.. Show the required net area calculation <br />�i�:-�'• assuming approximately 75% of the vent area is net. The required ventilation area ratio is 1/150 <br />of the attic area, or 1/300 of attic area if at least 1/2 of the vent area is more than 3' - 0" above <br />soffit or eave vents. <br />i <br />Qr 20. Specify makeup of one -hour fire resistive construction on the garage side for walls, ceilings, <br />1`5 oti posts and beams of garage supporting the dwelling. iV -9r:,j oij f'1 <br />V Structural portions of plans must be stamped and signed by a licensed structural engineer. <br />22. Retaining walls with more than 3' - 6" of unbalanced backfill and basement walls over 8' - 0" <br />tall are required to be designed by a licensed Washington State structural engineer. The design <br />is required to be signed and sealed. <br />Specify nailing per Table 23-II-B-1. <br />i <br />BCI floor joist plan is for lower floor. Provide new floor framing plan for main floor. Change <br />N all beam specifications on plans to match engineered floor design by Boise Cascade. <br />C21). Provide footings under all interior bearing walls and point loads. Show on foundation plan. <br />
The URL can be used to link to this page
Your browser does not support the video tag.