My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4526 FEDERAL AVE 2018-01-02 MF Import
>
Address Records
>
FEDERAL AVE
>
4526
>
4526 FEDERAL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2022 1:45:42 PM
Creation date
2/10/2017 4:41:41 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
4526
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
542
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 4, 1973 <br />Luther Child Care Center <br />4526 Federal Avenue <br />Everett, ashington <br />Review of: <br />Plans dated: <br />Plans received: <br />Edited 6 Reviewed By: <br />Project Architect: <br />DSHS #73310-513-3 <br />Working Drawings <br />February 16, 1972 <br />May 17, 1973 <br />J. Norris Pearson, P.E., Health Services <br />Division <br />Charles Morgan 6 Associates <br />Items followed by citation of a section number are requirements of the <br />Rules, Regulations, and Standards for Child Care Institutions as adopted on <br />November 22, 1967 by the State Board of Health, as amended to date. <br />Part B: Design Features Not Meeting the Standards of the State Board of <br />Health. <br />I. It is noted on Elevation Sheet AA-8 that roll linen dispensers are to <br />to provided at lavatories but in the specifications paper towel dis- <br />pensers are called for. Please clarify. <br />Soap and paper towels in approved dispensers (or individual cloth <br />towels for each child) shall he provided at each lavatory. WAC 388- <br />68-210(10). <br />2. Handwashing facilities must be provided in the kitchen. WAC 388-68- <br />210(12). See WAC 248--4-040(5). <br />3. Provide floor drain in walk-in freezer or slope floor to drain to the door <br />so that the box may be cleaned. PHS Bulletin 934 <br />REVIEW OF STATE FIRE MARSHAL <br />rhildren's quarters: <br />I. All doors on the corridor which require 20 minute door per Section <br />3304(h) of the Code shall have steel frames. Rediframe, as manufac- <br />tured by Evans Product Company, has been approved by the Code under <br />I.C.B.O. #2766. <br />2. Stair Doors 17 are part of the required one -hour stair and the doors <br />shall be the same as Doors 16 with a one -hour label for the doors <br />and the steel frames. <br />3. Doors 1 to counselor and isolation appear to have glass lights. The <br />maximum size permitted is 1200 square inches of 1/4 inch wired plate <br />glass in steel frames. <br />Reference Section 3304(h), Uniform Building Code, 1970 Edition. <br />4. To meet requirements for one -hour each truss shall be a tested <br />assembly to show the protection to the lower chord. <br />
The URL can be used to link to this page
Your browser does not support the video tag.