Laserfiche WebLink
4. <br />6 <br />6. <br />� <br />� <br />PUBLIC WORKS PERMIT COMMENTS <br />Connect side sewer per City Standard #601. <br />Connect side sewer per Cfty Standard #'s 601. 602, 604. <br />Connect all rooftop downspouts to the side sewer. <br />Connect rooftop downspouts to the drainage system provided for this lot. <br />8. Rooftop runoff must be discharged to a roof downspout inflltratbn system per City of Everett Stortn <br />Manual 3-2.62. The approxfmate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />9O. The conVactor must meet with the Public Works Inspector to discuss potential drainage routing prior to <br />beginning the project. <br />10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, sUaw <br />bales, swales, or erosion blankets. <br />18. <br />19. <br />20. <br />Install erosion control measures per Ciry of Everett Standards for small parcels <br />Remove erosion conVol measures upon completion of the project prior to final approval of the permit. <br />All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br />pertnitted site. No wasting of material is allowed on this building lot. <br />No dirt, mud, rocks or debris to be tracked onto roadway. <br />No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br />pedesUian travei. °R �A��`j <br />Adjust water meter box 1" above sidewalk grade. <br />Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan #'s 305A 8 306 on <br />this proposal's frontage as directed by the Public Works Inspector (f.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />Insiall a Type I concrete driveway per City of Everett Standard #307. <br />Pave driveway from the front property line out to the street paving. <br />Conlact the _ <br />sewer services. <br />Water District for connocting provisions for this building's water and <br />, 21` A catch basin as per City Standard Plan #402 with a gas trap per Standard Plan #410 is required for the <br />parking area. <br />22. <br />23. <br />If a sewer pump system is to be installed, lhe pressure line must discharge into a private manhole, then <br />gravity flow across the public right-of-way. <br />A sprinkler system is required for this building in compliance with the requirements of NFDA Stt+ndards <br />13D. <br />FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425-339-7403 / CLIFF AT 425-339-7404 <br />PWCommenls (� <br />