Laserfiche WebLink
F' <br /> n, <br /> ..,:.� <br /> ��-. . <br /> t^i - � <br /> ' PUBL/C f�f/OI�J�lS <br /> ,;: .�, <br /> ���' <br /> ay — <br /> �oxx <br /> ayv <br /> y �a October 28, 1992 <br /> �e � <br /> H�1 <br /> � N� <br /> y y~ L. Wayne Bond <br /> ox 8205 Florida Drive <br /> �t� Everett, Washington 9A203 <br /> ��g RE: Owner: L. Wayne Bond <br /> z H� Job Address: 8205 Florida Drive <br /> � y x Plan Check No.: 38355 <br /> Hy <br /> gy <br /> H <br /> O Cy N <br /> � �� Dear Mr. Bond: <br /> y oy In response to your application for a construction permit, your plans have been <br /> -- examined and you are advised that the issuance of a permit i� being withheld for the <br /> reasons listed below. These comments address building issues only, additional <br /> revisions or additions may be requircd by other departments (such as Utilities, Planning <br /> or Fire). Ail references refer to the 1991 Uniform Building Code, as am�nded by the <br /> State of Washington and/or Washington State Energy Cocie 1991, 2nd F�iition, unless <br /> stated otherwise. <br /> 1 "' <br /> ' L Plan set does not include foundation plan. Foundation plan shall show the <br /> following: <br /> �""'� A. Size and location of foundation vents. <br /> �"^� B. Size and location of crawl space access. <br /> C. Size and location of intermediate supports. <br /> 2. Building section does not call out all requireci components such as; floor <br /> �.,.,,� material, bottom plate, treateci sill plate, double top plate, stud spacing, truss <br /> spacing, moisture barrier (on walls or roo�, exterior finish, interior ceiling <br /> finish, etc. <br /> �""'�� 3. When eave vents are installed, baftling of the vent openings shall be provided. <br /> "'�'� Baffles shall extend 6 inches vertically above batts and 12 inches vertically <br /> above ]oosefill insulation. Baffles shall be rigid material, resistan[ to wind <br /> �.. ,,,. driven moisture. <br /> �v� � 4. Source specific exhaust ventilation shall be provided in each bathroom. <br /> Provide minimum 50 cfin exhaust fan ventecl to the exterior. <br /> 5. Plans do not specify framing method or material at new roof over the existing <br /> � structure. Provide roof framing plan. <br /> ""'� 6. The point of bearing of trusses may not be changed without the approval of a <br /> structural engineer. If the existing roof structure is stick framed, it is required <br /> that you provide sufficient information about the existing framing to determine <br /> if the existing fnming members will support the required loads over the <br /> increased span. <br /> CIT�� �F EVERETT• 3200 Cedar Street • EvereU, WA 98201• (206) 259-8800 • Fax (206) 259-8882 <br />