Laserfiche WebLink
w <br /> • s j � t , � � <br /> �. COMPUANCE <br /> ' REDUIRED � <br /> INSPECTION IMPORTANT:Please supply Intortnatton In the shaded boxes and check the appropriate <br /> APPROVED� <br /> circles.Disregard topics that don't describe your bullding or equipment.D9�LQ2 place <br /> checks In ihe two left columns. <br /> . a • • <br /> ❑ ❑ QQ Exterlor slab Insulatlon, il not located on the inte�ior, shail be R-10 (Table 6-2). <br /> � � �Exterior stab Insulatlon, if present, shall approved for below grade use and protected above grade. <br /> p ❑ QWalis,inc�cling rim joists>shall be insulated without Compression to{T8b(e S-2}: <br /> �R-15 hatt(Options 1,tp QR-y s iaption�tt, IV,Y,Vl,VI I) :. <br /> p ❑ �interfor below grade walis shaii be insulated wiihout compression to(Table B 2). : <br /> �R•75 (Options I, 11}', (�R-19(Options llt;IU,V.l'I,Ullj <br /> ❑ ❑ �o Vaulted cellings shaA be insulated wRhoui compressfon to R-3Q(Table fi-2, At�options) <br /> � p �i Skylight wall Insulatlon is installed and equivalent to the required wall R-values above. <br /> ❑ ❑ �z �epor retarders shall6r, instaUed toward the warm suHaoe as represented betow (5Q2.t.sf: <br /> Select one option for iloors,walls,and approptiate ceiiings: I ` <br /> Eloors; ,�.Plywocd W!exterior glue ', "�Poly(z a Mil) (� f�acKed batte , <br /> YVatls: Poty piastic(z 4 Miq Q Face-stapied, baaked batts Q PVA paint <br /> Ceitings:�Not reguired whe�e vetttilatian 6pace averages >32"a6ove insutation, <br /> Face stapted backed batts QPoty plastic (z 4 mill �.PUA paint ' <br /> ❑ � �Heating system afficlency and sizing requfremarrts shal(be met as rapresented below: <br /> ❑ ❑ Heat Pump eH�lency shall be mef undarihe toliowing compliance path (S.503.a): <br /> Q Spili system, alr source heat pump:iiSPF a 6.8,COP>3.0 <br /> Q Single package,;aU source';heat pump:HSPF z!s.s, COP'>3.6 I • , <br /> Q Water source heat pump:COP z 3.8: <br /> � Ground source heat pump C�P z 3A ! ' <br /> ❑ ❑ �s Central torce-al�furnace AFUE xating, as listed in the GAMA pireclory, shaU be: <br /> ;1�2 .78 (Options I;IIt,1V,UI,VII) (�z .88 (Option ill}� Qs 74(Opiion 1�) ' <br /> � ❑ e Non�central,combnstlon heat�ng systems shali have intermitent ignttian <br /> ❑ ❑ � Maximum heating system output {150%of design heat ioad) is V�� �"� BTU/hr:�5.503.2.2y <br /> p p a Hlgh efticlency torcetlalT Turnace (s 56,000 BTU/hr.oulput)may may axceed 150"loot DHC <br /> hecause: QGAMA listed AFllE is� 78+;4 per each'SODD BTUJhr outputlhat it exceeds!he �tiL. ' <br /> WSEC Insulatlon phase requirements: <br /> Inspected by: Date <br /> , . , <br /> ❑ ❑ �s Envelope Floars shall be insulated wfthout compression, and with support s 2A"�.C.to: <br /> {�jRi9{OptionS i, II, lll, IV, V) �jR25 iQP�ions VI, V{n : <br /> p p �o Non•vaulted,attic cellings shail 6e Insuiated without compression to: I See Tabie 6-2 <br /> �R-30 tOplions f, II, ID,IV,V, Vlp Q 838 (Optfon Vp <br /> ❑ ❑ �Ooor systems shali meet:(R�,�U.40 (AU options) <br /> Doortypes are (1) (�) S3� " <br /> _ <br /> Page 5 of 6 <br />