My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4803 FOREST DR 2016-01-01 MF Import
>
Address Records
>
FOREST DR
>
4803
>
4803 FOREST DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2017 1:20:34 PM
Creation date
2/11/2017 10:12:09 AM
Metadata
Fields
Template:
Address Document
Street Name
FOREST DR
Street Number
4803
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- __--- - - - -- -- - -�- - �------------------ ----- <br /> ,� <br /> , � �. <br /> Plan Check No. 55362 <br /> June 26, 1997 <br /> Page 3 of 3 <br /> 18. Habitable rooms shall have a ceiling height of 7'-6" in at least 5096 of the aroa. No <br /> portion of the room measuring less than five feet from the finished floor w the finished <br /> ceiling shall be included in any computation of the minimum azea thereof. The room(s) <br /> in the attic (as shown) do not comply with the minimum requirements for habitable <br /> space. Non-habitable spaces cannot be considered when calculating energy code <br /> comp(iance. <br /> 19. Specify safety glass in required hazardous locations. 2406 UBC (Show on plans) <br /> 20. The ridge board is required to be not less in depth than the cut end of the rafters. <br /> 21. Show the collaz tie connecdons. Provide calculations showing design to resist the live <br /> and dead loads, including connector size, spacing and edge distances. <br /> 22. Studs supporting two floors, a roof and a ceiling are required to be 3x4 or 2x6 at 16" <br /> O.C. (Table 23-I-R-3 UBC). <br /> 23. Note on framing plans: "Double joists are required under parallel bearing paRitions". <br /> 24. Show minimum 18" from grade to bottom of floor joists and minimum 12" to bottom of <br /> girders. <br /> 25. Show size of under floor access hole (18"x24" minimum). <br /> 26. Specify on the drawings, the shear wall material thickness. Size and spacing of <br /> fasteners, sole plate fastenings and hold downs. <br /> Upon resubmittal of the drawings, your applicadon will be given priority and plan re��iew will <br /> recommence. _ <br /> All required submittals shall be of sufficient detail and contain suffcient information to ensure that <br /> !he proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jeff Heilman <br /> Development Technician <br /> 7H:julriQ�vqkt9) <br />
The URL can be used to link to this page
Your browser does not support the video tag.