Laserfiche WebLink
� <br /> �: <br /> � ENGINEER/NG / PUBUC SERVICES DEPARTMENT <br /> �., <br /> Junr 13, 2007 <br /> Mr.7'crry I'ark <br /> Tcrry Dcsigns <br /> 1GS24 NG IOGth Strcc[ <br /> Rcdmond, \VA 95052 <br /> ProjccL• Two-story Additio i <br /> Job Address: 2501 Porest Vic�v Drivc <br /> I'lan Rcvicw No: C0705-03li <br /> Dcar Mr. Park, <br /> In responsc to your application lix construction perniit. 'hc plans havc bccn csamincd and you arc ad��iscd <br /> that a permit cannot bc issucd until thc following issuc� arc resolvcd. "fhcsc commcnts address building <br /> issucs only. Rcvisions or additions may Uc rcquircd by othcr dcpartmcnts (such as Utilitics, or Planning). <br /> Codc refcrcnccs cited includc ihc 2003 Intcrnational Residcntial Codc (IRC), thc 2003 �Vashington Statc <br /> I:ncrgy Codc (�YSGC), thc �1'ashington Statc Vcnlilntion and Indoor Air Quality Codc (�VSVIAQ) 2003, as <br /> adoptcd by thc City of lacrctt. 'I'hc rcicrcnccJ codcs includc currcnt amcndmcnts by du Statc of <br /> \Vashington. <br /> In ordcr for thc processing of cnur application tu continuc, it ��ill bc ncccssary to procidc ihc liuildin{; <br /> lli��ision���ill� two complete sets of drn�vings retlecting the corrections rcquested. <br /> Structural <br /> 1. Dciails 1 and 2 on Shcet A02 should bc rceised to matcli the aclual construction. <br /> 2. Flcadcr sim, spccics anJ gradc sBauld bc shown at all door opcnings and window opcnincs, sir :d f'or <br /> thc span to support thc roof and floor loads. <br /> 3. Drainagc lix thc Coundation perimctcr should Uc sho��m for thc runoff Gom thc wcst sidc stopc, per <br /> IRC R405. <br /> Construction <br /> l. "1'he specific prescripti�c meihod option for insulating ihe new additian should be sho��m on the <br /> dra�vings from�VSCC'�ablc G-l. <br /> 2. A themml brcak is requircd at thc slab iloor on Details I and 2 on Shcct A02, since the e�crcisc <br /> room will bc hcatcd (per the owner). The slab perimcter insulation should bc shown as water <br /> resistant, R-10 and coniinuous imder the perimctcr of the new slab, for a minimum combined <br /> distancc of 24 inchcs,per�1'SLC 502.L4.S. <br /> 3. A vapor rctarder should be installcd a[ new rxtcrior walls and between thc garage and tlre escrcisc <br /> room,per NSGC 502.1.G.G. <br /> 4. Thc garagc wall ncxt to thc cxcrcise room and thc nc��� stair shoulJ bc insulatcd ��ith R-1� minimum. <br /> per 7'ahlc G-l. <br /> CI'iY OF EVERE'fT• 3200 Cedar Street • Everett,WA 98201 • (��5) 257-6800 • Fax (425) 257-8856 <br /> ti',AIllulcv^.�urdl'0'11.c.iNS?�UII Fntc.iA'ire Ilydai <br />