Laserfiche WebLink
wood posts for public property and shall be located so that the bottom of the sign is a <br /> minimum of 7 feet above the curb. Where fire lanes are adjacent to buildings or <br /> structures and when approved or directed by the fire code official, the signs may be <br /> placed on the face of the building or structure. <br /> f. Where directed by the fire code official, specific areas shall be designated and <br /> ihose areas are to be marked with diagonal striping across the width of the fire lane. <br /> Diagonal marking shall be used in conjunction with painted curbs and/or edge striping <br /> and shall run at an angle of 30 to 60 degrees from one side to the other. These <br /> diagonal lines shall be in red traffic paint, parallel with each other, at least 6 inches in <br /> width and 24 inches apart. Lettering shall appear as above. <br /> 5. Premise Identification Easements - The correct address of each residence served by <br /> the easement access road must be posted upon a permanent sign at the street entry <br /> to the easement access. In addition, the correct address must be posted upon or <br /> near each residence in such a manner as to be clearly visible and legible from the <br /> easement access road. <br /> 6. Premise Identification - Premises shall be clearly identified by the correct address at <br /> the street entry. Buildings shall be clearly identified so as to be visible and legible <br /> from the access road. Individual apartments and suites, where applicable, shall be <br /> clearly and legibly identified from the access road. <br /> 7. Securitv Fence - Any security fence erected around the construction site shall be <br /> located so as to not obstruct any existing hydrant, fire protection equipment, or Fire <br /> Department access. If Fire Department access is obstructed, gates or other openings <br /> shall be provided for access. <br /> S. A fire hydrant is required within 350 driving feet of every one- or two-family dwelling <br /> structure. <br /> Add a fire hydrant at the south entrance. <br /> 9. Fire Flow - Minimum fire flow requirements for single and two-family residences under <br /> 3600 square feet is.1000 cpm; over 3600 square feet, fire flow is according to 2003 <br /> International Fire Code, Appendix B. <br /> 10. Construction and demolition of buildings shall be in compliance with the provisions of <br /> the 2003 International Fire Code, Chapter 14. <br /> 11. Permits are required from the Fire Department for removai and installation of <br /> underground fuel tanks. <br /> 12. Abandoned tanks shall be pumped out and the fuel properly disposed of prior to <br /> removal. No product or rinse water may be disposed of in such a way that it could <br /> enter the storm drains system. <br /> 8 �,�� <br />