Laserfiche WebLink
/ � � ' <br /> � � . <br /> 7. Provide foundation ventilation calculations, show size and location of vents on foundation <br /> plan. <br /> 8. Provide post and/or multiple studs under point loads, and show on plans. <br /> 9. Provide details of size and location of roof ventilation. Show all vents on plans. <br /> 10. The roof framing specified over the kitchen/bath/hall and family room is not deep enough <br /> for R-30 insulation plus a 1-inch air space. Provide size species and grade of new <br /> framing members. <br /> 11. Show required fire blocking on section views. <br /> 12. Show minimum and maximum height on foundation details. (42/52.1)(41/52.1). <br /> Prepare a response letter showing where each item in this correction letter is addressed on the plan <br /> set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will .' <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain su�cient information to ensure that <br /> the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, • <br /> �� <br /> Jef Heilman <br /> Development Technician <br /> CC: JBBK Design ' <br /> P.O.Boz I773 <br /> Evnen,WA 96206 <br /> DGDI�PLNCKM3T0./IIEILMAN09X%FRIDAY AVE Z/Z, <br />