Laserfiche WebLink
C ( ' . �• •� <br /> Page 4 of 4 <br /> C.O.E. # <br /> Date _ <br /> � Note on the drawings that all structural panel components of the house such as softwood, <br /> plywood, particle board, wafer board and oriented strand board shall be identified as <br /> "EXPOSURE l", "EXTERIOR" or "HUD-APPROVED". 400.1 <br /> I 1. Specify on the plans that all solid fuel burning appliances shall be provided with the following: I� <br /> a. Tight fitting glass or metal doors. <br /> b. An outside source of combustion air directly connection to the firebox, or tested and listed I <br /> per HUD carbon monoxide performance requirements. � <br /> 0 <br /> 12. Fireplaces shall be provided with each of the following: <br /> a. Tightly fitting tlue dampers, operated by a readily accessible manual or approved automatic <br /> control. <br /> b. M outside source for combustion air-ducted into the firebox, a minimum of six squaze <br /> inches and an operable outside air duct damper. <br /> 13. Note on the plans that the builder shall provide a three month etched tract radon monitor, <br /> installation instructions and radon information sheets at the final inspection. <br /> ADDITIONAL CC"+[MENTS <br /> Rev. 12•l I•95 <br /> JHLlS'C.doc <br /> H� <br />