Laserfiche WebLink
� , ,• I � I <br /> � • I <br /> 8. Glue laminated beam in living room is not shown on section view. It appears chat <br /> the floor joists are cantilevered over the beam, which would make the bottom of the <br /> beam less than 7'-0" above the finished floor. See Section 310.6.1 UBC. <br /> 9. Provide engineering for gravity loads prepared by a licensed WA. St. Structural <br /> Engineer. <br /> I <br /> 10. Show stepped foundation walls on elevation. Wa(Is with more than 3'-6" of <br /> unbalanced backfill are required to be designed by a licensed WA. St. Structural <br /> Engineer. <br /> 11. The front elevation view has a door penciled in, but it dce�not s}�ow on the plan <br /> view change plans to be consistent. <br /> 12. The engineering does not show the basement level. Provide lateral analysis and <br /> gravity loading for basement (see 1/9). <br /> 13. Roof framing plan shows stick framing, some details show trusses, clarify. If roof <br /> is to be entirely stick framed, bearing walls need to be specified and all loads traced <br /> to the foundation (see l�9). Ceiling framing needs to be specified. Beam supports <br /> and connections need to be specified. Show how overhangs on rake sidc of roof are <br /> supported. Show size, species and grade of hip rafters on covered porch and how <br /> they are attached to beam and the house. <br /> 14. The upper floor plan (sht. A2.2) shows "the roof below" incorrectly, revise plans to <br /> show correct confguration <br /> 15. Show roof pitch on all roofs on elevation views. <br /> 16. The water closet stool in all occupancies shall be located in a clear space not less <br /> than 30"(762 mm) in width. The clear space in front of the water closet stool shall � <br /> be not less than 24" (610mm) per section 2904 UBC. <br /> 17. Provide detail/section of interior and exterior stairs; label all components including <br /> guardrails and intermediate rails. <br /> 18. Provide the following on site plan. <br /> a) Side sewer location <br /> b) Water Service location <br /> c) Show new sidewalk behind existing curb and gutter (show all on plan) per <br /> standard 306 DCSSD. <br /> d) Cross section of driveway drawn to scale <br /> e) Detail of driveway cut per STD 308 DCSSD. <br /> ��-'J <br />