Laserfiche WebLink
' Washington State Energy Code:C��nponent Performance Worksheet,Type R3 O�upancies <br /> Haack Brothers Homes � � �C G U � <br /> Plan 2105 <br /> Heating System Size <br /> Ducts are located in unconditioned space� <br /> Conditioned FloorArea <br /> p�ps Equipment size over design load �oo°io � �. <br /> Conditioned Building Volumc 16840 Btu/hour output 25.190 <br /> Weather Station Everett Painc AFB � KW 7'4 <br /> Component Performance,R-3 occupancies Code Target Values Proposed Design Values <br /> Area UA Area UA <br /> Vertical Glazing U = 0.300 316 94.7 247 86.3 <br /> Overhead Glazing U= 0.500 0 0.0 0 0.0 <br /> Doors U= 0.200 38 �6 38 6.0 <br /> FlaWaulied Ceilings U = 0.027 1185 32.0 1185 36.7 <br /> Wall(above grade) U = 0.056 16�4 89.8 16i3 98.7 <br /> Floors U= 0.029 9z� Z6.� 920 23.0 <br /> Slab on Grade F = 0.360 0 0.0 0 0.0 <br /> Below Grade <br /> 2'depth,wall U= 0.042 0 0.0 0 0.0 <br /> 2'depth, slab F= 0.590 0 0.0 0 0.0 <br /> 3 5'depth,wall U= 0.041 0 0.0 0 0.0 <br /> 3 5'deplh, slab F= 0.640 0 0 0 0 0 0 <br /> 7'depth.wall U= 0.037 0 0.0 0 0.0 <br /> 7'depth. slab F = 0 570 0 0.0 0 0.0 <br /> Target UA Total 250 8 Proposed UA Total 250 8 <br /> Target Credds from Chpt 9 1.0 Proposed Credits from Chpt. 9 1 0 <br /> If the Proposed UA<_the Target UA, and the Proposed Credits From Chpt.9 are> 1 than the home meets the 2009 WSEC. <br /> Check other code requirements <br /> Cnpyi�yi�.t:oio 17511E@P1o�o�Dp�e�s�.on70)Cop�.ea�rypc�m�ssonimmWashm�ton5tatcUnrvervryEstensionEnergyProgram. (seecop�y�8h��sirictionof6 <br />