Laserfiche WebLink
� c <br /> ,uiy sa,2ooz <br /> left Heilmw <br /> City of Everott Public Works <br /> 3200 Ceder SVat <br /> Everett,WA 98201 <br /> Subject: Projxt: Beker <br /> lob Address: 4951 Glacier Lene <br /> Plan Check No: CO207-OM <br /> Mr.Heilman, <br /> As you requested,this response letter shows wherc each item is addrcssed on the two new ua of drawings. <br /> Each numbered rcsponse corresponds with each numbered cormtion. <br /> 1. Sheet 2,Detail#1. New imulation rcquircments. <br /> 2. Shat 1,Floor Plan. Add skylight(U�.58)in kitchen to mat light rcquircments. Existing door <br /> takes care of ventiladon. <br /> 3. Shat 2, Foundation/floor framing. Chenge Floor joists to 2x10 to accommodate R-30 insuluion. <br /> 4. Sheet l,Floor Plan. Note pertaining to�moke Detectors. <br /> 5. Shat 1,Note below Floor Plen. Alt windows M•ilI be new with a glazing U-factor of 0.40. <br /> 6. Shat 2,Detail#1. Insulation tight to boriom of floor. <br /> 7. Sheet 2,Fowidation Plen. Note referring to excavating of existing footing. <br /> 8. Shcet 2,Foundation/Floor framing. Girder is eliminated. <br /> 9. Shat 2,Foundation Plan. Note to drill and insert M4 reber into existing foundation. New foundstion <br /> faoting will be deeper than the existing. Contractor will have to use his'judgement for the best <br /> connection. <br /> It is our intention to meet or exceed the rcquirements of all adopted coda. <br /> if i can be of turther assistance in expediting this project,please call me et(360)435-7875. <br /> Sincercly, <br /> Dennis M.Funderb <br /> Aspenwoal Home Design <br /> 3737-226'"PI.N.E. <br /> Arlington,WA 98223 <br /> For: Chuck DeGraffenreid <br /> Renaissance Builders Inc. <br />