My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4711 GLENHAVEN DR 2016-01-01 MF Import
>
Address Records
>
GLENHAVEN DR
>
4711
>
4711 GLENHAVEN DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 4:23:11 PM
Creation date
2/11/2017 4:22:53 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENHAVEN DR
Street Number
4711
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ - <br /> Since the dens'ty of the on-site soil is variable, random soft pockets may exist and the depth <br /> and extent of excavation can best be deteimined in the field by the geotechnical engineer or <br /> " engineering geologist at the time of construcdon. <br /> The on-site soils contain a high percentage of fine-grained material �hich makes them <br /> moisture-scnsitive and subject to disturbance when wet. Therefore, the use of these soils as <br /> swctural fill should be lunited to favorable dry weat6er conditions. The contractor must use <br /> caze during site prepantion and the foundaaon excavation operations so that the underlying <br /> soils are not softened. If disturbance occurs, the softened soils should be removed and the azea <br /> brought to grade with compacted granular fill (structural fill). Consideration should be given <br /> to protecting the driveway and consuvction s[aging areas with an appropriate thickness of <br /> crushed rock. This surfacing may require additional material as the weather and construction <br /> traffic dictates. <br /> 9.1 Strucmral Fill <br /> - Structural fill is defined as any inorganic soil, acceptable to the geotecluiical engineer, <br /> compacted to the specified densiry ucider buildings, roadways, slabs, pavements or any other <br /> load-bearing areas. Structural fi!1 should extend beyond the outside edge of all foundation <br /> elements a lateral distance equal to the depth of supporting structural fill. Structural fill should <br /> extend horizontally beyond the edge of the pavement or footing areas a nw�imum distance of 3 <br /> feet before the start of any required fill slopes. <br /> Stivctural fill located under foundations, driveway and parking area should be placed in <br /> horizontal lifts not exceeding 12 inches in loose thicl�ess and compacted ro a minimum of 95 <br /> percent of its laboratory maxinrum dry density, cietermined in accordance with ASTM Test <br /> Designation D-1�57 (modified Proctor). The fiil materials should be placed at or within 2 <br /> - percent of the optimum moisture content. <br /> If fill is placed during wet weather or if proper compaction cannot be obtained, a select import <br /> material consistine of a clean, free-draining gravel and/or sand should be used. Free-draining <br /> fill consists of non-organic soil with the amo�nt of fine-grained material lunited to 5 percent by <br /> weieht when measured on the minus No. 4 sieve fraction. <br /> The contractor should note that any proposed fill soils must be evaluated by Associated Earth <br /> Sciences, Ir.c. (AESI) prior to d�eir use in fills. This wou]d require that we have a saznple of <br /> d�e material 48 hours in advance ro perform a Proctor test and deternrine its field compaction <br /> standard. Soils in which the amount of +"ine-grained material (smaller than No. 200 sieve) is <br /> greatcr dian approximately 5 percent (measured on the minus No. 4 sieve size) should be <br /> considered moisture-sensitive. <br /> Where fill soil will be placed on e�isting grades exceeding a slope inclination of �3H:1V, the <br /> slope should be benched and provided with a toe key. The benching is intended to ensure <br /> adequate interlocking between the ne�i� fill and esisting soils. <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.