Laserfiche WebLink
_ �:� � � _, ' <br /> � <br /> �; S'/ �� <br /> ENG/NEER/NG / PUBL/C SERUICES DEPARTMENT <br /> ,-Ly'�::. ���� <br /> ,� <br /> July 27, 200> <br /> Bao Trinh <br /> 934 Glenhaeen Drive <br /> Evcrett, WA 98203 <br /> Subject: Project: Trinh <br /> ]ob AJdress: 934 Gicnhaven <br /> :'la� Chcck No: C'O50',-003 <br /> Dear Mr. Trinh: <br /> In responsc to your application for a construction pcnnit, your plans have becn examined and you arc <br /> advised that ihe issuance o( a permit is bcing withhcld for thc rcasons listed bclow. These comments <br /> address building issucs only. Additional rcvisions or additions may bc rcquired by oUier departments <br /> (such as Utilities, Planning or Pirc). All references rcfer to the 2003 Interna[ional Residential Code, as <br /> amended by the State of\'Vashington :md/or Nashington State Lnergy Cocie 2004 Ldition, unless stated <br /> otherwisc. <br /> Li m•dcr for tLc proccssing of your applicalim� lo continuc, it �aill bc necessary to pro�•ide the <br /> IDuilding llivisiou «'ilL hro coniplcte ne«� scts of dra�riugs reflecting lhe corrections requested. <br /> 1: Change :dl codc references Io currcnt code 2003 lnternational Residential Ccxle QRC), and <br /> 2004 �Vashington Statc Gncrgy Code (\VSGC). <br /> 2_ Provide I10 volt smoke alanus in each bedroom and in the corridor or area aiving access lo <br /> eaclt separate slceping area. Alarms shal! be installed on each story and in basementslR313 <br /> IRC. <br /> 3. Show all openings in basement walls, windows, doors etc. <br /> 4. Basetucut plan calls out "2 s ►2 II.P. N2 joisis or TJI LQU." Basement framing is c�isiing'? <br /> Spccify aclual framinn. <br /> j. Verify footing under bearing wall in basement supportine upper floor load. Show on plans. <br /> G. Show all partitions in basentent. Desi�nate use of all spaces. <br /> 7. 13raced wall panels (I3WP) are rcquired at each end of each braced wall line and not morc <br /> than 25'-0" on ccntcr. The spacing a(the BNP on the addition exceeds 25' on ccnter. <br /> R. Thc walls on the soulh corner uf the existin; main tloor,(bedroon�/kitchen/dining room) do <br /> not provide the minimum rcquirement of wall arca for prescriptive compliance �vith Section <br /> RG02.20.1 �Vall I3racing. Provide lateral analysis prepared by a licensed Washington Statc <br /> Struc�ural Lngineer. Note: If Ihere is a gara;e door or large opening in the basenunt wall <br /> belo�v the kitchen/bedroom ii will also need to be considered by the s[ructural engineer. <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax(425) 257-8656 �2 <br /> n�ni ri.rr.eicu�m�u!,i w n„�n�,�,r,u ri i.�u��i�, <br />