Laserfiche WebLink
COMPUANCE " l � / • � <br /> � FEOUIRED � <br /> IN9PECT10N IMPORTANT:Piease au 1 Iniortnatlon In ihe shaded boxes end check the appropriate <br /> APPROVED� pp y <br /> circtes. Dlsregard toplcs that don't describe yDur 6ullding or equipment.�QI place <br /> checks In the two left coiumns. <br /> e <br /> � � • � <br /> ❑ �Extetlor siab Insuiatlon, H not/ocated on the lnter/or,s;iall be R•10 (fa61e 6-2). <br /> ❑ x�i,Exterlor slab Insulatton, 8present, shali approved for beiow grade use and protected above grade. <br /> ❑ e Walfs�lnc�dmg iim joists,shali�ba y'rsutated withoui compression ta{Tabte 8-2}: ' „ i <br /> _:;•�(]Ft-7s ban(options t.tl} ; C�-ys ippt(on�tL'tv,;0:VI,Vu) . , ` •,� ,,=x; ` <br /> ❑ Qs Intettbr below gtede walis'shalt tated wiihout'compression to (Table 8�2} � <br /> "rQR'15lOptions.i, Iq -19. <br /> �� . {Options III, IV,U.V!,VIi) , ,, , , <br /> ❑ o V8ulted C811ings shall be insulated wfttiout Comptesston to R�30(Table&2,All options) ' _ <br /> „ . <br /> ❑ ❑ Qi Skylight wall Insulatlon is installed and equivalent to the required wall R-values above. <br /> � � <br /> ❑ Qz Vapor ietarders shall be installed foward the werm surface as represented betow{50,2.1.6f; <br /> : Seiect one opt tor floors, walis,and_appropriate ca�Gngs:` <br /> . <br /> Fioors . Plyi��c,od W/exterior gtue �Poly(a a Mil) �j Backed s <br /> Wallsi ,r' .ly plastic(z 4 MiIJ `; Face-siapied,backed batts �VA paint <br /> Ceilings: ��ut required where verrtitation spaoe averages >12"above insutatior., <br /> (J Face stap(ed backed batts C,k'oly piastic(a 4 mA} Q,P,VA paint <br /> ❑ C � Heatthg system eft�ciency and slzlnB requiremer�ts shall be met as represented uelow, <br /> � ❑ �Heat Pump eHfdency shali tie met unda�the.tollowing compilanco path{S.503,a): <br /> . O Spltt system,air source;heai pump:HSPF.z'6.8,COP>3.0 <br /> ; •� Sfngle padcaga, air sou�ce heat pump:HSPF a 6.6, COP>3.0 <br /> . b Q Water sourcaheat pump:COP a;3.8 �,,; ` <br /> ' �Ground source heat pump COPa 3.0 � � ' ` <br /> ❑ Q Central torce�al�furnace AF'!JE rating,:as list in the GAMA Directory,shalt Be: <br /> ° Q2 .78(Qplions i, �i, IV,V!,VIIj �88 (Option III}1 Q=.74(OpUon 1� ; <br /> ❑ ❑ Qe Nonroentral,combustlon heating sysiems shap have iniermitent ignRion <br /> ❑ ❑ �jMaximum heating syster�output (1S0°!o of design heai foad� is 87I1�r. (S.503.2.2) <br /> ❑ ❑ �ie]Hlgh efliclency torceqair tumace (s`56,000 BTU/hr.outpul)may may exceed 750°leof DHL <br /> because: ,�GAM/�IistedAFUE is z 78+ t per each 50D0 BTUIhr outpui that it oxCeeds 1he �HL. <br /> WSEC lnsu/atlon phase requlrements: <br /> Inspected by� Dafe <br /> � � <br /> ❑ Q Envelop oprs shall be insulated w3thout compression, and with support s 24°D.C.to:� <br /> {�19(Options i. II, III, IV, 1� �R25(Optfons�I. Vlq <br /> ❑ Q Non•vaul ,attic cellings shail Be irsuiated wflhout compression to: <br /> 30{Optionsi, I1, IIl' IV;V Vlg See Table 6-2 <br /> � � Q R3B {Upt(on VI) �� <br /> ❑ ��]Door sysiems shall meet:�U.40 (AII options) <br /> Qoor types are (1)__..— ,_�(2)._...� ..�(3)_ <br /> Page 9 of 6 <br />