Laserfiche WebLink
t • <br /> Steve & Denise Goetz <br /> June 29, 1992 <br /> Paqe Two of Three <br /> 7.✓�There shall be a floor or landing on each side of a door. A <br /> , �% door may open at a landing that is not more than 7-1/2 inches <br /> '�='���j�C�j lower than the floor level, provided the door does not swing <br /> � over the landing. Landings shall have a width of not less <br /> than the width of the door. Landings shall have a length <br /> measured in the direction of travel of not less than 36 inch <br /> Group R, Division 3 and M Occupancies/3304 UBC. <br /> ���7, 8.✓A 50 CFM fan, vented to the exterior is required in a laundry <br /> room/302.2.1 V.I.A.Q. Code. <br /> S� i�7 9.�lans do not include typical section at garage. Provide <br /> detail from foundation to roofing. <br /> 3-�i��P�; lOY�lans do not show how the roof at the second floor and the <br /> S�* g roof over the garage are supported between the post in the <br /> garage and the point where the wall angles (next to dryer) in <br /> the utility room. <br /> 11.Plans do not show locations of multiple studs or posts under <br /> /�T�7j 'o concentrated loads from girder trusses or hip master trusses. <br /> � � Some concentrated loads occur over windows and doors. <br /> ��� Provide locations or multiple studs and/or posts. Design <br /> headers based on loads determined by actual truss layout. <br /> �� �S� 12.Plans do not show how attic ventilation requirements are met. <br /> 13.Plans do not show brick veneer detail. Foundation plan does <br /> not indicate how brick veneer is supported. <br /> v� .�,.(S 14.A11 exterior walls and main cross-stud partitions shall be <br /> p effectively and thoroughly braced to resist wind and seismic <br /> ��'� 1�� forces by one of the eight methods listed in Section 2517 (g) 3 <br /> UBC. Specifically those walls are the front and back walls <br /> of the livinq room, the walls on both sides of the bay :n the <br /> family room, the front wall of the den, and the entire front <br /> wall of the second floor (also see item #3 for garage wall) . <br />