My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4841 GLENWOOD AVE 2018-01-02 MF Import
>
Address Records
>
GLENWOOD AVE
>
4841
>
4841 GLENWOOD AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2024 2:17:34 PM
Creation date
2/11/2017 5:38:16 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
4841
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
InspectionTvpe Date Result Remarks <br /> 4841 GLENWOOD AVE <br /> Permit: PW0601-006 Status: lesued: 2/6/06 Finaled: To Records: <br /> Description: NEW HCUSE-LOT 5 PLAT OF WESTWOOD <br /> NoteslConditions: <br /> MiscPW Insp 71/27_I06 Violalion No dirt excavation, see notes <br /> Erosion control and building construciton only. <br /> Keep pump discharge for surface water on site at all times. <br /> All soil to be covered with straw or plastic. <br /> Need additional rock, constructin entrance. <br /> MiscPWlnsp 12/28106 <none> See notes <br /> Clean catch basins at bottom of driveway. <br /> Install catch basin sediment trpas. <br /> Sand bag water run-off drains. <br /> Straw mulch all exposed soil <br /> Install construction entrance to botlom of hill, 2"clean rock for entire length of driveway. <br /> MiscPWlnsp 113/07 Other Workmanship deficiency, see notes <br /> Engineered/geotechnical report on ecology block wall. <br /> Engineered erosion control plan. <br /> Celan existing storm drain outfall in Glenwood, one week for compietion, non-compliance result in <br /> Stop Work. <br /> MiscPWlnsp 2/2/07 Other Workmanship deflciency, see notes <br /> Cover ground with straw in front of house. <br /> Connect temporary piping on north side of house to catch basin, use screws. <br /> Fix piping in driveway. <br /> MiscPW Insp 6113107 Corr Reqd 24-hour power to temp pump, see notes <br /> 1)Must have power to lemporary storm pump at all times. <br /> 2)Must submit stamped engineering for ecology block wall over height(8'). This has been requested <br /> before, this is a one week notice for a STOP WORK ORDER, no work of any kind. <br /> Other 7/24I07 Corr Reqd N1all drain, see notes <br /> Wall drain behind driveway retaining wall wilt have to be uncovered to verify piping. <br /> MiscPWlnsp 7126I07 Ecology block wall, see notes <br /> Certification of Ecology Block Wall: <br /> City of Everett requires special inspection and written approval of installation of ecology block wall (5 <br /> blocks high). <br /> Must be turned in to Ciry of Everett prior lo Final Certification by Geotech or struclural engineer. <br /> Final PW 7126/07 PartialApproval OK temp occupancy, see notes <br /> Public Works OK for temporary occupancy. <br /> Final approval is subject to compteting driveway, storm drainage, ground cover/landscaping, Geotech <br /> approval of ecology block wall. <br /> Other 10/2/07 Corr Reqd Erosion control, see notes <br /> Cover all exposed soii wilh slraw or mulch. <br /> Ciean storm drain ipe plugged at entrance to driveway. <br /> Other 8119108 Corr Reyd See notes <br /> Non Compliance with Hearing Examiner to Installlrepair block retaining wall per approved plans <br /> REPAIR SCHEDULE IS REQUIRED <br /> MiscPWlnsp 8128I09 Corr Reqd Removing block wall-see notes <br /> Inspected Removal of block wall along driveway-Corrections: <br /> 1. Must replace block wall along driveway so dirt slope is no more than 2:1 slope <br /> Permit: U0602-002 Status: Issued: 2/6I06 Finaled: To Records: <br /> Description: NEW HOUSE <br /> NoteslConditions: ' DON070ISTURB�REAEASTOfTHf290'CONTOURLINE <br /> S:\MMcleodlCrystal\InspectionRecords.rpt 3/10/2011 Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.