Laserfiche WebLink
� <br /> Glemvood Tcrracc <br /> Filc Numbcr 126994 <br /> May !Z, 1994 <br /> Page IS <br /> 71�e fill surf'acc should be expcctcd to setlle ovcr timc. The design oC the surfacing in front of ihe building <br /> should talce into account the potential difl'erential settlement of this surface. These setdemcnts will largely <br /> be apparent in non-pile supported slabs and sidetitialks. Wc recommend Uiut "transition" slabs be used <br /> bctwecn pile and non•pile supportcd slabs(such ns sidewalks),to prevent vertical oETsets due to differential <br /> senlement. The Iransition slab is a reinforced structural slab thnt is doweled into the pila supported <br /> structure nnd the non-pile supported slab. As settlemcnt occurr, the dowels act as hinges allowing <br /> movement withoul vertical offsets at the slab joints. <br /> There is some risk involved with the use of auger cast-in-place piles,due to the presence of rubble or other <br /> obstructions that underlies the site wilhin the old fill. We expect, while using an auger type drill, refusal <br /> may occur in the older fill. Pilcs tertninatcd on rubblc or with shallow rcfusal dcpths will need to bc rc- <br /> drillcd. We recommend that design criteria for re-drilling should be providcd with the job plans and <br /> specifiqtions,such that the contractor may know how to spnce redrillcd holes nround lhc abandoned pile, <br /> if nceded. All abandoned piles (groutcd but not end bearing) in the fill should not bc connected with the <br /> grnde beatn system. <br /> �Ve have calculatcd pile bearing capacitics based on penelmtion into the ouRvuh and laterel pressures witl� <br /> an estimatcd detlection. We have providcd these values in Table 1 bclow, showing t}Pical pilc diamMers. <br /> 'I'hcsc valucs use soil/pile interaction only; lhe capacity oC the pile may be controlled by lhe structural <br /> design. A vcry import3nt design par.tmeter is the potcntial for do«�ndrag on Utc piles. Downdrag would be <br /> caused by the fill settling around Uie pile and trying to puU U�e pilc down��ith it. The downdmg forces are <br /> dep�:ndcnt on the dcpth of the fill. 'Il�e pile structural design oPtlic pile should account for tliae do�mdrag <br /> forces. That is, the allowablc design of die pile should be enough to take the total load shown in the pile <br /> capacity column. TFie valucs shown in Table 1, wcre calculatcd using an embeddment depths of 3 and 7 <br /> feet into the underlying glacial soils. Higlur design capacities can bc achieved using larger diamMer pilcs <br /> and more pcnctration. lf higher valucs arc ncafed, we can provide them based on actual anticipated pile <br /> loading. <br /> NE.LSON-COUVRETTE&ASSOCIATES, INC. <br /> FEB-23-1996 12� 1l1 206 481 2510 ?6: P.17 <br />