Laserfiche WebLink
�" <br /> Michcl <br /> Plan Check No. C0408-023 <br /> September 2, 200�4 <br /> Page 2 of 3 <br /> 7. Braced wall pancls shall be located at cach cnd of each braced wall line and not <br /> more than 25' on center. <br /> 8. loist under parallel braced wall panels shall be doubled. <br /> 9. Specify rim joist material. Provide detailslsections of truss joists. <br /> 10. Provide post at end of beams in crawl space or provide detail for beam pocket. <br /> 11. Guards shall have intermediate rails or omamental closures which do not allow <br /> passage of a sphere 4 inches or more in diameter. <br /> 12. There shall be a tloor or landing at the top and bottom of each stairway. Show on <br /> plans. <br /> 13. Handrails shall be provided on at least one side of each continuous run of treuds or <br /> flight with four or more risers (R31 L5.6 IRC). <br /> l4. Provide section/detail for exterior stainvay. Show all components. Specify rise, <br /> tvn, guard, handrail, etc. <br /> l5. Provide smokc alarms in all sleepin� rooms and in the corridor or area giving access <br /> to each separate sleeping area (in new and existing residence). Alanns shall be 110- <br /> volt with battery back up. Alarms shall be interconnected. R313.1, R313.L I IRC <br /> Please prepare a response letter showina where each item in this cort�ection letter is addressed on <br /> the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient inform�tion to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jeff Hcilman <br /> Development Technician <br /> S:ULindsay\\VORD\HL•II.�IAPI.APlan chcck`o C030S-0_3.doc <br /> �`V <br />