Laserfiche WebLink
. � ' --. ._-. <br /> ------- ------- ------------- ------_ <br /> -------------------------- -------__---------__ <br /> _-____=-------------------------------------------------- <br /> WATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 07/27/93 <br /> FILE: C:\\WATTSUN5\�WSFILES\\NEWFILE HOUSE ID: BLANK <br /> ====r______________________________________________________�___________==____ <br /> Site: 2503 COLUMBIA Analyst: VICKI BABIN 258-8279 <br /> EVERETT, WA Jurisdiction: SNOHOMISH COUNTY <br /> � � - Utility: SNOHOMISH COUNTY PUD # 1 <br /> Homeowner: House Type: Multi-family <br /> Floor Area: 3600 ft2 <br /> � ) <br /> Builder: BLANK N BLANK Weather Data: EVERETT, WA <br /> Climate Zone: 1 (Seattle, WA) <br /> (206) 339-6794 <br /> ________�_�___�____________________________________________�____�_�___________ <br /> � . , <br /> The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. <br /> • REFERENCE PROPOSED <br /> COMPONENT PERFORMANCE 516 463 Btu/hr-F <br /> ENERGY BUDGET *** *** ]:Wh/ft2-yr <br /> --_____�________________ <br /> --------------------- <br /> _�____________________________________________________ <br /> REFERENCE DESIGN <br /> Reference <br /> Component Value X Area = UA <br /> --------------------•------------------------------------------------- <br /> Floor U-0. 029 1881 54.5 <br /> Glazing @15� U-0.400 540.0 216.0 <br /> Doors U-0.200 i14.0 22.8 <br /> AG Wall U-0.058 2834 164.4 <br /> Ceiling, Attic U-0.031 1881 58.3 <br /> Infiltration ACH=O_350___30600ft3 (_190_6) <br /> Reference UA 516 <br /> ----------------------------------------------------------------------------- <br /> PROPOSED DESIGN COMPONENTS <br /> Component Description Value X Area UA <br /> ------------------------------------------------------------------------- - <br /> Floor R30 vented Joist 16oc U-0.029 1881 54.5 <br /> Glazing @10$ **NW ALUM VINYL W/ARGON U-0. 360 257.0 92.5 <br /> **NW ALUMINUM SD VINYL/WARGON U-0.490 100.0 49.0 <br /> Doors Metal R-5 base case U-0. 190 54.0 10.3 <br /> **FOAM CORE METAL PANEL U-0.220 60.0 13.2 <br /> AG Wall R19 STD Lap Wood U-0.062 3017 187.1 <br /> Ceiling **R38 blown attic STD 5/12 pitch U-0.030 1681 56.4 <br /> ---------------------------------------------------------------- <br /> Items in parentheses not included in COMPONENT PERFORMANCE totals. <br /> ** Denotes non-standard values - check calculation of thermal value. <br /> _____________________________________ Page i =__________________________________ <br />