My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6412 COMMERCIAL AVE 2016-01-01 MF Import
>
Address Records
>
COMMERCIAL AVE
>
6412
>
6412 COMMERCIAL AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2017 12:04:33 AM
Creation date
2/12/2017 12:04:24 AM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
6412
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . <br /> . � . � . , . , <br /> � COMPLIANCE <br /> • REOUIRED � <br /> INSPECTION IMPORTANT: DQ.dQI Place checks in the two lett columns. <br /> - APPROVED� <br /> �?��!Y!�!�'�':�'.�'!4"!'f'},W�'�.7�� <br /> p p �2 Exposed foam Insulatlon shall comply as follows (S.502.1.4.7): <br /> ❑ Protected with metal or plastic flashing, or other suttabie material thal extends below grade. <br /> p Insulation is approved tor sub-grade, exterior use and properly installed. <br /> p ❑ �Alrtlow between fresh air ports and the whole-house fan ensured by undercut doors/grills(VIAQ,S.302.6.4) <br /> p p �Loosefill Insuiatlon OK it (5.502.1.4.5): <br /> ❑ maximum ceiling slope not>3 in 12 <br /> p230"ot clear distance from top ot boriom chord to underside of roof sheathing at the roof ridge. <br /> p p �6 mit black polyethylene ground co�er, shall be Iapped 12" at joints and extand to foundation wall <br /> p O Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br /> ❑chimney pNon-IC rated recessed Iights: 1/2"to combustables,3"to insulation. <br /> O O � ttic hatch shall be insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br /> 0 p Attic access shali have wood dam or equivalent to retain loose iill insulation in attic(S. 502.1.4.4) <br /> � p II exterior doors (except 20 minute doors) shall be weatherstripped (S.502.4.3). <br /> p ❑ o Service hot&cold vtater plping in uncondftioned spaces shall be insulated to R-3(S.503.11) <br /> p p � Service recirculatton hot water plpinp in unconditioned spaces shall be insulated to Table 5-12 levels. <br /> � p 2 Heat pump thertnostat shall have progamahle capability(S. 503.8.3.5) <br /> O O �hermostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br /> O O Readiiy accessible,automatic or Manual means provided to restrict or shut-off Heating input to each <br /> zone or floor during periods not requiring heat (S. 503.8.3.1). <br /> �O p s ontrols for backup heat prohibit similtaneous operation of the primary system (S. 503.22(3)). <br /> � O e echanical ventilatlon system shall have proper timers, andlor switches(VIAQ,S.302.3). <br /> O p echaNcal venttlatlon ducts shall have R-4 insulation in��ncondi�ioned spaces (VIAO,S.302.5) <br /> � p a echanical ventllatbn supply ducts in rnnditioned spaces shall have R-4 insulation(VIAQ,302.5) <br /> O O upply ducts shall have volume dampers,or the equivaleiri,to balance system(S. 503.6). <br /> O O �PP�Y and retum aly ducts shall have sealed duct joints in uncondit�cned spaces (S, 503.10.2). <br /> 0 p �VAC plenums,supply, and retum air ducts shall have H-S insulation(Table 5-11,All options) <br /> � 0 z lectric water heater(s) shall have(S.5042.1, 504.3,504.4) : <br /> ❑separate power shut-ott <br /> ❑ 1987 NAECA Lable on tank <br /> ❑noncompressible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br /> O O �howers and lavatorles shall Ifmtt tlow to s 3.0 gailons/minute (S.504.8.1). <br /> p p �Swimming poo�s(S.504.5) shall have: <br /> p readily accessible OWOFF switch (pump, heater) ❑Pool cover ❑Piping insulated to S.503.11 <br /> O O ���f��Places (VIAQ, S.402.3)shall have: <br /> 0 6 square inch combustion air supplyduct w/accessible damper directly connected to the fire box <br /> 0 � <br /> e S I difuellblu9n g app iance(s) (VIAQ, S.40�2.)1 shall have�ue damper <br /> �Tight titting glass or metal doors <br /> DOutside combustion air source directly connected to the tire box <br /> pException: Non-direct,4"diameter, dampered, combustion air source:allowed only tor(1) new stove <br /> installations in existing homes where obstructionsprecludes direcl combustion air,or(2) Central <br /> heating systems located in unheated spaces. <br /> 0 p � Three month,etched track radon monftor, printed instructions, and intormation sheets shall be supplied <br /> to the single tamily dwelling or first iloor units ot multi!amily dwe!�ings by the general corriractor(VIAQ,S. <br /> 5022.1), <br /> WSEC Final phase requlrements: oate <br /> Inspected by: __ <br /> Page 6 of 6 --— <br />
The URL can be used to link to this page
Your browser does not support the video tag.