Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connect side sewer per City Standard#'s 601, 602, 604. <br /> 6. Connect ali rooftop downspouts to ihe side sewer. <br /> 7. Connect rooflop downspouts lo lhe drainage syslem provided far Ihis lot. <br /> 8. Roo(top runol(must be discharged to a roof downspout infillration system per City of EvereU Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br /> more details. <br /> 9. The conlractor must meet wilh the Public Works Inspector to discuss potenlial drainage routing prior to <br /> beginning the projecl. <br /> 10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, stra�v <br /> bales, swales, or erosion blankets. <br /> 1'. Install erosion control measures per Cily o( Everett Standards tor small parcels <br /> 12. Remove erosion control measures upon completion of the project prior to (inal approvai o£the permit. <br /> 13. All excavated material from foundation, sidewalk and drivev:ays shall be hauled to an approved, <br /> permitled site. No wasling o(material is allo�ved on this building lot. <br /> 14� No dirl, mud, rocks or debris to be Iracked onto road�vay. <br /> • 15. No building malerials lo be slacked on siden�alks and side�valks to be hept clean and open for <br /> pedeslrian lravel. <br /> 1G Adjust water meter box 1" above side�valk grade. <br /> 17. Remove and reptace curb, gulter and sidewalk as per City of Everetl Slandard Plan #'s 305A R 30f on <br /> lhis proposafs frontage as directed by the Public Works Inspector(i.e. all unused driveways and an�� <br /> broken or damaged area must be replaced�. <br /> 18. Inslall a Type I concrete driveway per City of Everett Standard #307. <br /> 19. Pave driveway from lhe front property line out to the street paving. <br /> 20. Contacl lhe Water District for connecting provisions for this building's �vater and <br /> sewer services. <br /> 21. A catch basin as per City Standard Plan it402 with a g2s trap per Standard Plan#t410 is required for U�e <br /> parking area. <br /> 22. If a sewer pump system is to be installed, lhe prossure line must discharge into a private manhole, then <br /> gravity(low across the public right-of-�vay. <br /> 23. A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RF�NDY AT 425-339-7403 / CLIFF AT 425-339-7404 <br /> r-::�;crt.a:..�J; .r <br /> \\\ \'1i <br /> I � <br /> \ i <br />