Laserfiche WebLink
`COMPLIANCE � � ` j ' t � ' � ` <br /> � REOUIRED � <br /> INSPECTION IMPORTANT:Please supply Infortnetlon in the shaded boxes and check the a ro riate <br /> APPROVED Pp P <br /> � clrctes.Dlsregard toplcs that don't descrlbe your bulldlnp or equtpment.DO NOT place <br /> checks In the two left columns. <br /> � ! � � ` � <br /> ❑ ❑ �Exterlor sleb Insulatlon, il not located on the lnterlor,shall be R-10 (Tabie 6-2). <br /> p p �Enterior slab Insulatlon, il present, shall approved for below grade use and protected above grade. <br /> ❑ ❑ QWalls, inck�dirig rim joists,shall be insulated wittaut compresaion to{Tablb 6-2} � <br /> (JR-i 5 batt (Opfwns l,ttj �R-79 (Op►fon 111,IY,�,VI,VIl) J ' ' <br /> ❑ ❑ �interio�below grede walis shalt 6e insutated'without cortlpression to (Table'8 2�: <br /> QR-i 5 (Options t, II) ':: QR-19(OptlOhs Of, N,V;Vl,VII) . <br /> ❑ ❑ �o Vaulted cellings shaU be insulated wrthoui compression to R�3D jTable&2, All optbns} <br /> ❑ ❑ Qi Skylight wai: Insulatlon is instalied and equivalent to ihe required wall R-values above. <br /> ❑ ❑ �z Vapor reta�ders st all be Installed toward the'warm suiface as represeMed bstow(502.L6): <br /> Seiect o�ie option for iloors, walls,and appropriate ceilings: <br /> Floors; Q Plywuod W/exterior glue ; Q Poly:(a 4 Mil) ,(� Backed batts <br /> Wails: Poly piastic{z 4 Mil) � Face-stapied;:backed batts Q PVA paint <br /> Ceilings:�Not required whereVentilation space averages >72"above insulation. � <br /> Face stapied backed batts �Poly plaslic (� 4 mi!) ' Q PVA pai�t <br /> ❑ ❑ �Heating system effL.iency and sizing requlrements shall be met as rapresented belaw: <br /> ❑ ❑ Heat Pump eH�lency shail be met.underthe following compllance path (S.503.4): <br /> � Split system, air source heat pump:HSPF 2 8.8,COP>3.8: <br /> � Single'padca9e,air sour,� neat pump:HSPF z 8.6, COP�3.0 <br /> Q Water source heat pum�r COP 2 3.8' <br /> � Ground source heat pump COP 2 3.0 ` ° ' ' ' <br /> p p QQ Central force-a{r turnace AFUE rattng,ae i�ted in the�AMA Directory, shap be; � <br /> �S� .78 tOpUons I, lt, 1V,VI,Vliy (�'2 .8s (Optbn III}} ; �z.7d(OpUon V) <br /> ❑ ❑ s Non�central,combustlon heating systems shaH have iMermitent ignition : <br /> ❑ ❑ � Maximum heaUny system output,{150%of design heat bad) is 6TU1�r.(S,503,22) <br /> ❑ ❑ e High etticlency forced�alr turnece (s 56,000 B7UJhr.output)may may exceed 150%of qHl <br /> because: �GAMA listed AFUE is z 78+ t per eaCh 500D BTlllhr output ihat it exCeeds the DHL. <br /> WSEC Insu/atlon phase requirements: <br /> Inspected by: Date <br /> , • . � <br /> ❑ ❑ �Envelope Floors shall be insulated wfthout compressan, and with support s 24"�.C:to: , <br /> �R19(Options i, II, III,1V, V) Q R25(Options Vi, Vti} � • ; <br /> p p �o Non•vaulted,aqlc cellings shail be Insulaled wUhout compresslon to: See Table 6-2 <br /> QR•30{Options I, II, IIi, IV,V, VII) 0 p38 (Opt(on V(j � <br /> � p p �i Door systems shail meet:Q U.40 (All options) <br /> Doortypes are (1j (2) (3) <br /> Page 5 of 6 <br />