I
<br /> �
<br /> �
<br /> . . �..;,�'?
<br /> '•� Seetion 1A05(a) : Dtinimum windov size shall be 1/10 oE thc floor area, or 10 squarc �
<br /> fect minumin. Ilalf oC thc required window arca shall 6c openablc.
<br /> In bathrooms, N�ter clocets compartments, l�undry room::, and �imilar
<br /> ^ooms a fan connected directly to the outside, and capable of
<br /> producing S chang�a of air �er hour may be ins[alled in�tead of
<br /> , openablc windows.
<br /> :�'�Section 1407(b): Nnended. Minimum cciling height shall be 7'G", except hallways,
<br /> bat}�roons, and water closet rooms, shall havc a minimum hci9ht of
<br /> 7' meusur.ed to thc lowest F>rojection from t)ie ceilling. ,
<br /> ; Section 1407(b) : Every dwellin9 unit sh�ll have at least oiie roem which shall have -
<br /> not less than 150 square fcet oF floor area. Othcr ha6itable roo:�s
<br /> except Y,itchens shall have an a�ea of not less than 70 square fcet.
<br /> � . Section 14U'(c): No habitable room other thun a kitch n shall be less than 7 feet in
<br /> . any dimension, �
<br /> . � ".. ,. ���-� G�=- _: _- .�i•��,. �J(�ti"i:._ ';;r r.� Z, �.r �� 6
<br /> � l .� �''.I?a'ti(..1;N:r�.' � rn
<br /> . . . ,�F.� �, . ��. �.;- �,'-:s,:•_� �� -r+�r .�_r�:c , '� `- .'� � � �
<br /> _ ;�: .! �,Y ',_
<br /> . I�,, ..i:.i . ,- ..�. . ".' Ar.i� i.: �c� .�. -...:r; " .'_ i� i.;. ..� �_�r..it: . .
<br /> � Section 1412: A carport entirely ooen on two or nore sides need not have a fire '
<br /> separation between the carport and the house. Windows shall not be
<br /> openable, and doors shall be sel£ closing.
<br /> , = Section 1413: � �
<br /> £very dwelling sh'all 6e pYovided with aoproved detectors o: products �
<br /> of combustion other than �hcat, cotiorsing to U.B.C. Sta�dord No, 43-6, :
<br /> u�ou�ted on the ceiling or wall wi;hin 12" frem ceillinq at a point
<br /> centrally located in the area givir.q a.ccess to roo�s used for sleeping �
<br /> purposes. Some buildings nay reqire more than one unit.
<br /> - Section 1707 (c): Amended. 23alconies,.�landinge:; exterior stair�.ays, and sinilar
<br /> surfaces excoced to'the weather and sealed underneath sha11 be
<br /> aaterproofed. tJhete rlywood is used in areas subjec. ,o weather
<br /> exposure �and/or adverse moisture conditions such as sof=its, caroort,
<br /> ' gable ends, porches, and similar areas, it s:�all have a grading �
<br /> minimwn of C-C Exterior or an aoproved eqvivalent. "Shon" or ni!1
<br /> certified" plywood is not accep[able for any of the above uses or
<br /> . for any structural use such as subiloors, roo: or wall sheatSina,
<br /> , underlayment,!etc.
<br /> .i�Section 1711(b): A water clo�et compartment shall be not less than 30" wide and have
<br /> at lcast tuo feet of clear space in front. �
<br /> Gr�
<br /> �Section 1�11(d) : All showe� areas shall bc finished with a smooth nonabsorbant material
<br /> . . such as,ceramic tile, portland cemen., or approved equal, to height �
<br /> , of 6' ahove the floor: This matrrial shall be installed over a material
<br /> _ not addersely af:ected by moisture such as water resistant plaster board.
<br /> Fire stopping is also required in this azea as specified in Section
<br /> ' 251�f).
<br /> � Section 1711(c) Doo s and panels of shower and bathtub enclosures �hall be substantially
<br /> coq'structed from shatter resistive materials, fiinged doors shall open
<br /> o fward, unobstructed. �
<br /> � • J'�Section 1716: 1 unenclosed floor and roof o enin s;
<br /> andings; balconies or porches which9are�moreathan130einchessabove
<br /> . grade; and roo:s used for other than service of the building, shall
<br /> bc proEected by a guardrail. Guardrails sh�ll be not less than 42
<br /> lnchec in height. Open guardrails and stair railings chall h�ve
<br /> intermediate rails or an ornamental pattern such that a 9-inch �'
<br /> diameter sphere cannot pass through. The hcight of stair railings '
<br /> � , may be as specified in Section 3305(i). �
<br /> . ✓�Section 230 (e); A.�equate anchorage of thc roof or bcams to eolumns or w�lls, and of �
<br /> walls and columns to the foundation to resist over turning, uplift
<br /> , - and sliding, shall be provided in all cases. .
<br /> . . . I ' 1
<br /> �I
<br />�
<br /> i
<br /> i7
<br />
|