Laserfiche WebLink
I <br /> , �.- . � �" ' � <br /> l�/�?-; '�,;', � , . c <br /> , • <br /> 3.18 [� Ri�pair enistin� or install new nosls to bear upon above gr.tle concrete pier blocks to maintain pmper support lor <br /> sLuclure�vhere eKisting are missing or damaged,at ar below grade. pncluAes po2hes, decks, carports). <br /> 3.19 (] Rcasunabty IevM soil of cnwl space. <br /> 3.20 [� Open ll�r tound;rtiun direclly 6ehind porch. Remove inlecteA end joist. Repair <br /> IounJetion plales, sub Iloors (�tihere necessary), and remove debns Imm Insidr porch. Chemically treat all areas <br /> � ol int�•sWtion �silh Z'� chiordanc in light od. Install vapor barner o�cr sal imdcr porch. Install at least one <br /> 8" x 14" vent sciernrd with 1:{' galvanized hardware cloth to area under porch. . <br /> 321 �] Rernnve sidmg ahove porch and fiil eracks or void between house and porcl�. Instnll metal flashing and water prool <br /> eompounds tn prrvent �vater leaks. <br /> 3.2? ❑ Recnnstruct porches to bear upon toncrete looting. (Sagging porch elevations to Ee correcled to within 1"ol level <br /> �o allua p�oper�s:rtc� nin�olF �vhere applicibie). <br /> 3.23 ❑ Replace porch deck with all new"standard or belter" 1 z A T&G fir tlooring (all single <br /> lenglhsi. Finish drek rLsrs with trim ot "Dul Nos" stop material. Paint new malr.�ials with "rez" as a scalant <br /> lgdmst H•Calharin��. <br /> 3.24 [� RepCirc poreh railing with all new No. L tinish materials. Paint new materials with <br /> � "�ci'sualarl. <br /> 325 �i�":�,d� porch or step tootings to 6ea upon above grade cencrelr., Replace all mtUed <br /> m damaged malenals. � Replace_=.... c�..J� � steps complete. <br /> . 3.26 ❑ Remove ezis!ing wood skirting or skirting combinations around and replace <br /> wilh a non•celiulose malerial such as "flexboard." Instalt sufficient piers and posts and 2 x 4 backing for snund <br /> conslruction. 2 s 4 backmG to he a minimum of 2' on center with hottom framing apprerimately 6"above eztaior <br /> grade. "Flrr�board"or e^maalent to be a minimam thickness o( 3!1G'. Rep�irireplace any damaged supports, <br /> bcams or joisl cnds �or sound construction. <br /> 3.27 ❑ Remove old form lumber, trash and tellulose debtis frem soil of crawl space and install a .004 mil plastic vapor <br /> barriec Plastic io ;;� (lat upon the soil without ezte�tling up on piers or foo�ings. Al�ow a siz inch lap where <br /> joined and hotri in pixe with bricks or stones, <br /> � 3.28 ❑ Install new pia�.tic vipor barrier as required tor complete coverage. Allow a siz inch lap where joined and hold in <br /> placc with �.icks or stones. <br /> 3.29 ❑ Chemically trcat all areas ol infestation to include new materiais and existing materials adjacent to reconshcetion <br /> with an .pproved �_Yungicidal, ❑ Termite (damp wood), [; Powder Post Beetle, ❑ Moisture Ant . . , trealing <br /> chemical such as i l coppemapthenale"20", ❑ 590 penWchlorophenol in light oil, [J 29; chlordane in light oil. <br /> NOTE: All chemical treating to be perlormed prior to the installation of plastic vapor barrier. <br /> -3.30 ❑ Chemiraliy treat soil ol all crawl areas and along footings wilh I°;chlordane (water emulsion)accordin6 to attept• <br /> ed standaid tcrm�tr eperator procedures lor ihe conlrol of sublerrancan termdes. <br /> 331 ('] Chemically trrat lor the rradiwtion ol carpenter ants,by dritting method,all areas of infr.stalion to include ezterior <br /> � w:dl, ,tlic. c.;nvl <�;,�,•. �r basement with 2°J Chlordane and !�.i96 LinUanu m spr.ry base. Treat yard areas with <br /> 2�'o Chlardanc �.va;er cir�uiaiuN. <br /> 3.32 ❑ Aper the work has bcen completed by the pest control company,the pest control firm shall furnish the department <br /> . � ol H.U.D. with n certihcition siGned by the oest control company operator indicating lhat all work has heen per• <br /> latmeA accordin¢ to the detailed specifications. <br /> 3.33 [� �Iter ihr work has hcrn completed hy the pest control company,the pest rontrol lirm shall lurnish the owner wdh <br /> a standdrA Washington Slale Pest Control Association dearance certihcalion. <br /> 3.31 ❑ In the event the home owner peAorms his own work. a dearance certification may be oblained irom lhe original <br /> inspecling firm at currenl reinspeclion fee of E <br /> 3,35 ❑ Remove wood supports tor plumbing/heating ducts, elc.and install pipe strap or other stable suppoR o(tontrete <br /> block or other non�ccllulose materials. <br /> 3.36 �Gean, repaii,c.ulk and treat all existing gutlers to prevent water leaks. Replace missing or damaged downspouts <br /> and splash block5, (Splash blocks to be installed to facilitate water drainage ,way froin house). All downspo❑ts <br /> Icading to splash bloc6s am to have elbows instailed. ❑ Replace mt or damaged section <br /> �3.37 ❑ Remodrl raRer Wils nnd insWil new 4 x 5 wooden, treated cuUers (treat S���tcr interiors aRer installation with as- <br /> i phalt rool cuatingl. Install new downspouts to include splash blocks whi[h are to be instdlled to facilitate water <br /> draiwgc a��ay Irom house. All downspouls leading to splash biocks arc to have elbuws installcU. <br /> 3.38 [] Replace exisling gutlers wilh new 4 x 5 wood, tmated, otfset gutters (tmat Ruttcr intcriors aftcr instaliation with <br /> asphalt �ool coaline). Install new downspouls to include conr.rete splash blocks where missing er damaged. (Qlf- <br /> � sct g�dlers to bc nul Icss ttian �b"1. All downspouts leading to splash blocks are to have cl6ows iastalted. <br /> 3.39 �] Instali roof edpe Ii.ishhig br proDer watcr run�oll into new guUers. <br /> 3.40 x( Rem��ve exisfing rooiing. <br /> 3.41 �Replace damaged nr rottrd sheathing as necessary and...(see lollowing two items). <br /> 3.42 �insta�l a new complete 235 Ib. 3 tab compasition roo(wilh metal edEe Ilashings. <br /> 3.43 �] Install a o�w compiele hot moD root (two layers of 15 Ib. felt and one layer of 30 Ib. IeIU to include meta� ed�e <br /> IlasliinE;s, sr.uppers, nownspouts and spiosh blocks. (Splash blocks to be inslalled to faciliWle waler drainage away <br /> Irom housc). All down•,puuts leading to splach blocks�re lo havic elbows installed. <br /> 3.44 � Rool, guUers, downspoids and plumbing IeLks a�e Aeleted Irom �hese Pest Cnnlrol rcauiremcn�s. <br /> 3.45 �] Cormrlions lo Ilnor ei�•vations would �Csuit in eztensivc damage to upper walls,etc. <br /> 3AG �No diagnm is mrJudeJ in these specilications, . <br /> 4A �_� (Sce alL�ched pa�tr Nu.4 lo�additional items). <br /> n.t pQ Rcf+u� er.Wl 6./� We// cover. <br /> + � <br />