. � � <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#G01. <br /> 5. Connect side sewer per Cily Standard #'s G01, 602, 604. <br /> 6. Connect all rooftop downspouts to ti�e side se�ver. <br /> 7. Connect rooftop downspouts to the draina�e system provided for this lot. <br /> 8. Roo(top runoff must be discharged to a roof downspout infiltralion system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25'long. See attachment for <br /> more detaiis. <br /> �I The contractor must meet wilh the Public Works Inspector lo discuss potential drainage routing prior to <br /> bec�inninc� the projecl. <br /> 10) Install erosion conlrol measures as determined by Ihe Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Install erosion �:ontroi measures per City of Everett Standards for small parcels <br /> 12_.l Remove erosion conlrol measures upon completion of fhe projecl prior to final approval of the permit. <br /> 13. � All excavated materiat irom (oundation, sidewalk and drive�vays shall be hauled to an ap��roved, <br /> permilted site. No wasting of malerial is allowed on this building lot. <br /> 14`\ No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15` � No building materials to be stacked on sidewalks and side�valks to be kept clean and open (or <br /> pedestrian lravel. <br /> 16. Adjust water meler box 1"above sidewalk gradc. <br /> 1 17,� Remove and replace curb, gutler and sidewalk as per City of Everett Standard Plan t.'s 305A& 306 o�i <br /> � this proposal's fronlage as direcled by the Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area must be repiaced). <br /> 1 Fi. Install a Type I concrete driveway per City of Everetl Standard#307. <br /> 19. Pave driveway from the front properry line out to the street paving. <br /> 20. Contact the Water District for connecting provisions for lhis building's water and <br /> sewer services. <br /> 21. A catch basin as per City Standard Plan#402 with a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be inslalled, the pressure line must discharge into a private manhole, lhen <br /> gravity flow across the public right-of-way. <br /> 23. A sprinlder syslem is required for this building in compliance with the requiremenls of NPDA Standards <br /> 13D. <br /> P17C51'i150I5 � <br /> Z �� <br />