My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6107 DEXTER AVE 2016-01-01 MF Import
>
Address Records
>
DEXTER AVE
>
6107
>
6107 DEXTER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2017 2:16:25 PM
Creation date
2/12/2017 3:11:35 AM
Metadata
Fields
Template:
Address Document
Street Name
DEXTER AVE
Street Number
6107
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 14, 1974 <br />b1r. �9alter E. Nelson <br />3607 Federal Avenue <br />Everett, iVashington 98201 <br />Dear Mr. Nelson: <br />�I:+. �:.0 . . .. <br />CITY OF <br />everett <br />c�rr N��� • :aa•ena� <br />CVERCTi. W�SHIN6T0'1 <br />9tl:�1 <br />INSPCCTION OCP�RTN[NT <br />On April 1, 1979 and again on hiay 10, 1974 this Division made <br />an inspection of property owned by you at 6107 Dexter Avenue, <br />Everett, Washington. <br />On April 3, 1974 a report of the first inspection was sent to <br />you which outlined the deficiencies noted in the first inspec- <br />tion. <br />The inspection of May 10, was essentially an electrical <br />inspection made by hir. Lawrence Dougherty, the City Electrical <br />Inspector. <br />A copy of his reoort was left with Dirs. Nelson at the time the <br />inspection was made however the following list is a copy ef <br />Mr. Doughertys report: <br />1. Switches have been altered v:hich voided the UL <br />approval of the panel. <br />2, Circuits are overfused. <br />3. All side panels are illegal so there should be a <br />new service installed large enough to accomodate <br />the connected load and enough circuits so there <br />zre no sub panels or doubling of circuits. <br />q. The water heater must be connected with K10 wire <br />and the discharge from the water heater relief valve <br />must be piped to the floor. <br />The correction of these deficiencies will suffice if the property <br />is to be used as a single family residence. <br />If the property is to be used as a duplex please refer to our <br />letter of April 3, 1974 for further requirements. <br />Yours truly <br />Robert K. Royce <br />Housing Conservation Supervisor <br />IIy <br />Douglas A. IIudden, nspec or <br />
The URL can be used to link to this page
Your browser does not support the video tag.