Laserfiche WebLink
� �� <br /> 4" � H <br /> H ' q�' ="wµa•.,'. <br /> � �y - a <br /> H �c ,�,; �,,r;„ <br /> � y � . . � ... .. � . .� . . <br /> � H �1 <br /> VJ Hr <br /> L�1 O [i1 <br /> Hl7 <br /> OH <br /> H � g FIELD REPORT <br /> (�]Y (� <br /> aH� Project: Soltner Residence <br /> t� y z Written by: Keith Soltner <br /> y y Date: Hay 2, 1989 <br /> � �� Time: 1:OOpm � � ,�i „ , ,:�� <br /> Weather: Sunny �.,;;' �` �. � <br /> � �j Temperature: + 60 deqrees F. " "- ,Y'r" �'� �`� � <br /> . - <br /> �p y 'k.'.. .�,. <br /> Present at Site: �� � � ti� <br /> Lc� - <br /> Hike C ��, 7S <br /> GarY ,<` � <br /> Eric <br /> Ken Jackson, Building Inspector <br /> Keith <br /> "z' - <br /> {lork in Proqress: Rou�h carpentry, sidin9 <br /> Observations: <br /> - The folloxinq was reviewed by Ken, Hike and Keith and agreed upon: <br /> - The headers over the Living Raom NindoWs in the southwest corner Will he <br /> '�1 strapped at the top and bottom xith a minimum 18-qaqe strap extendinq onto <br /> ' ' each header 6" and nailed v+ith 16d nails. I <br /> - The end studs on each side of the fireplace at the hiqh wall connectinq the � <br /> ' ' Living Room and Family Room walls is closer than 2" to the masonry. These <br /> ' ' Nill be relocated aNay from the chimney to allow a 2" clearance. � <br /> 1 - The Family Room roof header is within 2" of the masonry fireplace. Hoving i <br /> this xill cause damaqe to the roof and flashinq. To separate the masonry <br /> ' from the roof, 1/2" Type "X" gypsum board xill be installed betxeen the <br /> framinq and masonry. <br /> � � - The double rafters over the Dininq Room bearinq the gabled roof beam <br /> 1 I supporting che qable roof ridge a:e not on hanqers at the garaqe and <br /> � firerlace supports. Hangers r+ill be installed. <br /> t�' - The. 4x12 beam supportinq the Family Room deck must be strapped to the 4x12 , <br /> column in the r+est r+all of the Master Bedroom. Two straps as described for <br /> � the Livinq Room r+ill be used. <br /> 1 `��t <br /> ' - All shear r+alls, as indicated on the Framinq Plans, rrill have the nuts y <br /> removed from the anchor bolts; xashers installed and the nuts reinstalled. r�; <br /> This occurs on the loWer floor only. ,,,,�c� <br /> - k + 6" long piece of base plate is missing on the south Wall of the Naster .� I1 "�^ M <br /> Bedroom at the landinq of the stairs to the loWer level. This xill be , y�� i� <br /> replaced. �"}� <br /> � ` ',.�x.� <br /> - The 4x12 in the south Wall of the Haster Bedroom must be strapped on the , <br /> east side to the adjacent eall stud and top plate. Straps will be as �;.'���A�� t^� � <br /> indicated above. �*' � '�''~ '` <br /> ,:. ,�,. i <br />