Laserfiche WebLink
FeUruary 7 , 197d <br /> urv oF <br /> everett <br /> rpj';dY�J<1Y'C.'310 Company crtv r�eu . ..v.enos <br /> L:�JX C EVCPCTT. WAv11iNGTJ1: <br /> �.3dnonds, Washington 93020 `a:°' <br /> ir.sr.c:io:. ocruarnr:nr <br /> RE: 1012 Ed�•�ards Avenue <br /> Everett, F7ashir.gton <br /> FkiA 561 - 201846-203 <br /> Gentlemen: <br /> The following items must be corrected for the building <br /> permit to be issue�: <br /> 1. F7indow sill in bedroom No. 2 cannot be ovcr <br /> 48inches above the f1ooL. <br /> 2 . Window in IIedroom No. 1 , minimum �oidth allo�•red <br /> is 22 inches. <br /> 3 . Correct above windo�,�s . <br /> 4 . Install ne�o �oindoca, minimum one-tenth �loor <br /> area, one-half oper.able, or an exllaust fan, <br /> 5 air changes per hour in the bathroom. <br /> 5. Install windota or fan in laundry room me�ting <br /> minimum requirements as noted for bathroom. <br /> 6 . Rafters are overspanned and approximately <br /> 36 inches on center. Install one rafter Uetween <br /> existing or brace roof fron partitions or ne�a <br /> beams. <br /> Sinccrclv <br /> John H. Farrens , Jr. <br /> Inspection Supervisor <br /> Jfii�j nit <br />