My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6511 ELLIOTT WAY 2016-01-01 MF Import
>
Address Records
>
ELLIOTT WAY
>
6511
>
6511 ELLIOTT WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2017 6:47:42 AM
Creation date
2/12/2017 6:47:35 AM
Metadata
Fields
Template:
Address Document
Street Name
ELLIOTT WAY
Street Number
6511
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � <br /> Ltr. B. Menehan (C0303-010) <br /> March 24, 2003 <br /> Page 2 <br /> 7. Tlnder-f.00r ventilation shall be approximately equally distributed along the length of at <br /> least twu opposite sides. Per UBC 2306.7 <br /> 8. Provide details and sections specific to the floor system you are using. <br /> 9. Provide TJI details in plan set. <br /> 10. Show floor framing under fireplace. <br /> 11. The ends of each joist shall nave not less than 1 'h" of bearing on wood or metal. <br /> 12. TJI does not have an 8" floor joist. Specify depth and grade of specific floor joi�ts. <br /> 13. Provide 110-volt smoke detector with battery back up in the room open to the hallway <br /> when ceiling height is 24 inches or more above the hallway. <br /> 14. Provide braced wall panels perpendicular to the wall along b� lroom #2, bath #2 and the <br /> master bedroom. <br /> I5. Solid blocking required under braced wall panels that are perpendiculaz to the floor joists. <br /> 16. Details 2, 5 and 7 on Sheet AS do not appear to provide bearing or resistance to lateral <br /> movement. Please clarify. <br /> 17. Foundation walls with more than 3'6" of unbalanced backfill are required to be designed <br /> as a retaining wall. Provide design by a licensed Washington State Structural Engineer. <br /> 18. Insulation baffles shall extend 6" vertically above batts, and/or 12" vertically above <br /> loose-fill insulation. Detail this requirement on plan set. <br /> 19. Provide wall section showing flat ceiling. <br /> 20. Provide attic ventilation calculations. Show ventilation requirements on plans. <br /> 21. Provide header size at front entry or specify cantilevered trusses. <br /> 22. The ridgeline is shown off-center from the house in plan views but the truss detail shows <br /> the same pitch on both sides. (As do the elevations) <br /> 23. Provide Washington State Ventilation and Indoor Air Quality noles on plans. Show all <br /> exhaust fans and specify how whole house ventilation is to be provided. Location and <br /> details should be on plans. <br /> 24. Specify thickness of swctural plywood sheathing, moisture barrier and siding on wall <br /> sections. <br /> 25. Provide minimum 36" landing at all exterior entrance/exits. Show on plans. <br /> tIIDITLYC1:hISTR/IIEI111:\n'/Catol.ola�n511 F.WOTf wnr� 2/j <br /> ✓ <br />
The URL can be used to link to this page
Your browser does not support the video tag.