Laserfiche WebLink
i <br /> Augusc 30, 1972 ,\ ' <br /> Merriaether Garden:; &oarding 3io�e � ` <br /> Three locations (GveretC, Kirkland, Taroma - See Cover Lettcr) <br /> Edit•ed and Revieucd IIy: Harry TSrenan, ArchitecC, Health Services Divisiun <br /> Project Architect: Ray Merri��ether, Rirlcland <br /> P.eview of: Revised Prelii�inary Drawings, DSlIS �`;2336 <br /> Pl.ans dated: Au&ust 10, 1971 <br /> Plans received: AugusC 16, 19i2 <br /> ltems follor:ed by citation of: a secCion number are rcquirements nf thc Stand,+cds, <br /> Rules and ReBulations for Boardin� Ho;aes as adopted on ?I3rch 11 , 19G0, Uy Chi� S�ate <br /> Board of Health, as amended to datc. <br /> Part A: Addil•ionnl Information and/or PS�terial Necdrd for keview Purpose.^.. <br /> No dumpster stora�e location or refuse ur garbage storage is s}�own <br /> tor thc Evereet siCe. Please clarify. <br /> Part B: llest�n Fcatures Not Af_eting the Standards of the State 6oard of Hea1Ch. <br /> 1. Food Service Facili.ties: <br /> a. The single Cank dish washin^ nachine indicaCed in the drawings does <br /> not appear capable of handlir.g all of L-hc dishes l'hat �aill 6e re- <br /> quired to feed 233 persor.s three times each day. (S;AC 248-84-030(1) <br /> b. There is not adequal-e dining spacc for 233 persons even if all <br /> nvailable space in the adjoining Lounge and cra:ts area were used <br /> and if there was to be two seatings. (F7AC 248-16-140(5)) <br /> c. There is not adenuate refrigeration or freezer storage for 700 mnals <br /> per day. (IdAC 248-84-010(2)) <br /> d. Bulk food storage space is not ndequate to provide Che most efficient <br /> and economical mcans of purchasing. <br /> e. If you have any questions concerninr the above food service corimenCs <br /> piease contact our Nutrition Consultant, Dirs . Clare t•::Cann, i�lephoue <br /> 753-5947, Olympia, �?ashing[on. <br /> 2. In order L•o minimize accidenCal falls and to provide adequate assistance <br /> to Uourdels, the grab bars at water closeCs shall be about 24 inches <br /> lon� and 7ounted on each side oF the waCer closet starting 3 inches ahead <br /> of ttie waker closet and 34 inctics to the floor and sloping upward to 1? <br /> inches aluad of the �+ater closet and 54 inches to the floor. <br /> (�IAC 248-�G-130(3)) <br /> 3. A grab bar placed horizontal to the side of each bathtub is needed as <br /> wcll grab bars on three sides of each shower to minimize falls. <br /> (k�AC 248-16-130(3)) <br /> 4. The room layout of typical unit "A" shows the two heds on [he lc:t hand <br /> side of Che room to be less thnn thc required threc fceC aiparL•. <br /> (b'AC 248-1G-120(G)) <br />