Laserfiche WebLink
COMPUANCE <br /> • • j � f • � <br /> RE�UIRED � <br /> � �� INSPECTION <br /> APPAovEn� �MPORTANT:Please supply Iniortnatlon In the sheded bozes and check the approprlate <br /> clrcles.Ulsrepard tapics that don't descrlbe ypur building or equipment.D9Z1QI place <br /> checks in the two Ieft cotumns. <br /> , � . , . <br /> ❑ ❑ QQ Exterlor siab Insulatlon, N not located on fhe lnterior, shall be R-10 (fabie 6-2). <br /> � � �i Exterlor siab insulatlon, il present, shall approved tor below grade use and protected above grade. <br /> p p e Walfs,inc�di�g rim;pists,shali 6e insutated withoui�ompression to{Tabie&2} , _ � <br /> �'(�R•15 hatt (Options 1.ti� �R-19 (Optfon 111, tV,V,'Vi,VA)' ` `' - ' <br /> p p �Intetlor below gretl6 walis shalt he insulated without compress3onto (Table 6 2): �; <br /> . ; �R-15 (Optior�s I,lij . �R•19(Options III,1V,V.W,Vtl) ` <br /> ❑ ❑ �o Vaultetl cailings shall be Insulated withoui compressbn to R�30(Table 6-2,'Ail options)" ' <br /> p p Qi Skylight wall Insulatlon is installed and equivalent to the required wall R-values above. . <br /> ❑ ❑ �]z Vepor retardets shall be Installed towa�d the warmsurlace as represented betow t502.i.6); <br /> SetecFone option for tloors,wal(s,and appropr(ate cailings: . <br /> Fioors; :lywood W/exterior giue Q Poly{a a MI17 � Badced batts <br /> Walls: ` Poty piastic(z 4 MiIJ Q Eace-stapled,backed batts : �PVA paint <br /> Ceilings: Not required where ver8ilatan spaCe averages>12"above insulation. <br /> Face stP.pied backed baYs _ Q Paly plasC�c (� 4 rruT� ,� PVA paittt <br /> ❑ ❑ 3 Heattng system efttciency and sizine tequirements shall 6e met as represented below: <br /> ❑ ❑ �Heat Pump ettic.Nency shail be met under the following wmpllance path{S.503.4): ��r�,�y� :: <br /> < >� Split system, air.sourca heat pu pp:HSPFa 6.8,COP>3A ��� � <br /> Q Single package, air source heat ump:HSPF a 6.6, COP>3.0. <br /> . � Water source heat pump:COP a 3.8 .� . <br /> � Ground source heat pump COPa 3A ~ �r Z <br /> ❑ ❑ �s Central force�air furnace AFUE rating,aslisted io the GAMA Direc(ory,shall be: <br /> ,�2 Je(Opttons I, It,IV,Vl,Vlq �2 .88 (Option III}} �a.74 (Option V) , <br /> ❑ ❑ e Non-centrai,combusqon heatingsystems shail have inte�mitent `gnition � <br /> ❑ ❑ � Maximum heating system output (150°0 of design,heai foad� is�__BTUmr. (S.503.22) g� <br /> ❑ ❑ �e Hlgh efflciency forced•ai�fumace (s 56,000 BTUIhr.output)may may exceed 150%of pHL <br /> ; 6ecause: QGAMA listed AFUE is z 78+ S per each SODD BTUIhr output lhat il ex:eeds 1he OHL. <br /> WSEC Insulatlon phase requirements: <br /> lnspected by Date <br /> � • � }�I . <br /> p p Q Envelope Fioors shall be insulated without compression,and with support s 24"O.C.to:• - <br /> �R19(Options i,II, III, iV,V) Q R25(Options VI, Ulp <br /> p �Non•vaulted,attic cellings shall beinsulaled wRhout compresslon to: See Table 6-2 <br /> �R•30 (Optlons i, II. IIi; IV,V, Vil} Q R36 (Option VI} <br /> � � �i Door systems shail meet:�U.40 (All options) <br /> DoortYPes are (7j.L�—�tz).'.`i�.�..:.:_�(31 n. ,� �. : <br /> � � .-;��a a�s,a.::; <br /> Page 5 0l 6 <br />