F f <br /> CITY OF EV'RETT <br /> BUILDING DEPARTDIENT <br /> PLAN CORRECTION SHEET <br /> DATE May 22, 1986 IJSE <br /> OiVNER Alan ostman USE ZONING <br /> CONTRACTOR FIRE ZONE <br /> DESIG,IER OCCUPANCY GROUP <br /> JOB SITE ADDRESS OCCUPANT LOAD <br /> TYPE OF CONSTRUCTION PLAN CHECK N0. s6/1656a <br /> In response to your application for a permit, your plans and specifications <br /> have been examined and you are advised that the issuance of a permit is <br /> withheld for the reasons hereinafter set forth. NOTE CAREFULLY: Answer <br /> questions and make explanations by correctinq original plans , and ne�a <br /> plans must be submitted to the Building Inspection Department . (This sheet <br /> must be returned with original plans and specifications or they will be <br /> filed as new business . ) <br /> Item No. UNIFOR�t BUILDING CODE 1982 EDITION COD9 SEC. <br /> 1. Prints submitted are not readable. <br /> 2. Foundation walls with unbalanced backfill more than 3'6" <br /> high must be designed by a state licensed structural <br /> engineer (except for full :�eight basement walls) . Height <br /> of concrete walls at lo�oer floor is unclear. <br /> 3. Lower floor concrete walls must be furred and insulated to <br /> R-19. <br /> c�1t.J � <br /> Jac E Frets <br /> P1 s Examiner <br /> I <br /> Pa;e_of_ <br />