My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1718 ENGLAND AVE 2016-01-01 MF Import
>
Address Records
>
ENGLAND AVE
>
1718
>
1718 ENGLAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2017 8:44:50 AM
Creation date
2/12/2017 8:44:33 AM
Metadata
Fields
Template:
Address Document
Street Name
ENGLAND AVE
Street Number
1718
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tGcotcchnicai Enginccnng Evaluation <br /> England Avenuc Lot <br /> � June 2,2005 <br /> NGA File No. 41 I805 <br /> Pagc 9 <br /> r than une inch total and I/2 inch differential betwecn adjacent footings or across a distance of about 30 <br /> 7 <br /> fcet. <br /> i Lateral loads may be resisted by friction on the base of the footing and passive resistance against thc <br /> � subsurface portions of the foundation. A coefficient of friction of 0.3� may be used to calculate the base <br /> friction and should be applied [o the vertical dead load only. Passive resistance may be r.alculated as a <br /> triangular equivalent iluid pressure distribution. An equivalent fluid density of?50 pounds per cubic foot <br /> � (pc� shoulJ be used for passive resistance design for a Ie��el ground surface adjacent to the foating. This <br /> ICVCI SUf�BCC SIIOUI(I l'XIL`0(I a distance equal to at Icast thrce times the footing depth. These recommended <br /> Ivalues incorpontc safety factors of 1.5 and 2.0 applied to thc cstimated ultimate values for frictional and <br /> passive msislance, n:spectively. To .ICIIIL'VC �I115 VBIUC Of [�assive resistance, the foundations should be <br /> Ipoured "ncat" against the native medium dense to dense soils or compacted fill should be used as backfill <br /> againsl lhe front of the footing. We rccommend that the upper one-foot of soil be neglected when <br /> Icalculating the passive resistancc. <br /> Structural Till <br /> IGeneral: We do not anticipatc large scale fill placentent for this project; however, fill placed bencath <br /> I found:rtions, pavemcnt, or other settlement-sensiti��e stnictures should be plxed as swcwral fill. <br /> Structural fill, by definition, is placed in accordancc with prescribed methods and stnndards, and is <br /> monitored by an experienced gcotechnical professional or soils technician. Field moniroring procedures <br /> � would include the performance of a representative number of in-place Jensity tests to document the <br /> .ittainment of the desired degrec of rclative compaction. Thc arca to receive the fill shoidd be suitably <br /> I <br /> � prepared as describcd in the Site Preparation mid Grading subsection prior to beginning fill placement. <br /> I Materials: Stn�ctur:�l fill should consis[ of a �ood quality, granular soil, fine of organics and other <br /> dcletcrious matcri.�l and bc well graded ro a maximum sizc of about thrce inches. All-wcather fill should <br /> � contain no more than tive-percen[ fines (soil finer than U.S. No. 200 sieve, basec' on tlmt fraction passing <br /> � the U.S. 3/d-inch sievc). The use of on-site soils as structural fill should generally be feasiblc, but will be <br /> dependent on material moisture content at the time conswction takes place. The on-site soils should be <br /> ablc to be used as stn�ctur.il fill provided it is near the optimum moisturo content. We should be rctained <br /> to evaluate proposed stnictural fill material prior to constniction. <br /> � <br /> NELSON GEOTECHN/CAL ASSOC/ATES, INC. <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.