Laserfiche WebLink
.�� <br /> August 3, 1971 <br /> cirv or <br /> ever�tt <br /> CItY 111LL � $}9.8983 <br /> F.V[liCTT. WASNINGTON <br /> J & B Plumbing ea�o� <br /> 1 NEI'f CTI011 OLPAPTM ENT <br /> Route 1, Box S/3J <br /> Lake Stevens, Washington 98258 <br /> Dear Plr. Blackett: <br /> A courtesy inspecti � was made on your work at 1912 Gverett Avenue on <br /> i•fonday, August 2, 1971. Due to the numerous code vidlations and <br /> poor workmanship, a "Stop Idork" or.der was posted on the building for <br /> the plumbing. This was done to give es a chance to contact you before <br /> the work progressed any further. <br /> Some of the violations are: <br /> 1. Air chambers not installed as required. <br /> 2. Acid waste and vent piping not identifiaUle. <br /> 3. Non approved piping used in acid waste lines. <br /> 4. Vertical wa9it and vents not plumb. <br /> 5. Trap in vent pipe. <br /> 6, idater piping not run parallel with building lir.es. <br /> 7. Several joints in C1 waste lines improperly aligned. <br /> 8. Vent terminated less than 10 feet from air intake. <br /> 9. Very poor workmansliip throughout. <br /> The acid dilution tank shall be installed in the system for the protection <br /> of the City sewer system. <br /> Since you l�ave chosen to appeal to the Board of Plumber Examiners, the <br /> "Stop Work" will stay until their ruling. <br /> The Board meeting is scheduled for Thursday August 5, 1971 at 7;00 p.m. <br /> Sde will meet in room 203 of Everett City Hall. <br /> Y�urs truly <br /> Uean Pittman <br /> Inspector of Plumbing & Sewers <br /> DP:eb <br /> cc; RoUert G. Honerl:amp, Designer & Project Manager <br />