Laserfiche WebLink
T:i?'R�IAL PERFORMANCE CRITERIA <br /> Project: McDonald's. - Broadway Avenue, Everett, Wa 93-310 <br /> HEAT TYPE: CLIMATIC ZONE: I <br /> Electric Resistance <br /> x Other - Gas <br /> ► /\T= 50 DEG. F. <br /> ---------------------------- --------------------------------- <br /> ASSEMBLY TABLE AR.SA U x A U X A <br /> U-Va(or F) SF. (or LF) x/\T <br /> -------------------- ----------- ---------- <br /> WALL 0. 25 3178 794 . 5 39725 <br /> ROOF/CEILING 0. 035 2798 97 . 93 4896. 5 <br /> PERIMETER SLAB INSULI 0. 56 266 148 . 96 7448 <br /> ---------------------------------------------------------------- <br /> CRITERIA TOTAL: I 52069 . 5 <br /> U X A= 1041. 39 <br /> PROPOSED DESIGN: <br /> ---------------------------------------------------------------- <br /> ASSEMBLY U-VALUE AREA U x A U x e1 <br /> (SQ.FT. ) x /\T <br /> -------------------- ---------- ---------- ---------- ---------- <br /> -------------------- ---------- ---------- ---------- ---------- <br /> WALL 0. 0570683 2651 151. 28806 7564 .4032 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> ROOF\CEILING 0. 0475856 2798 133 . 14451 6657 .2254 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> WINDOW 0. 65 457 297 . 05 14852 .5 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> DOOR- GLASS 0.49 42 20. 58 1025 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> DOOR- HOLLOW METAL 0.59 28 16. 52 826 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> UNINSULATED SLAB 0.73 266 194 . 18 9709 <br /> -------------------- ---------- ---------- ---------- ---------- <br /> ---------------------------------------------------------------- <br /> PROPOSED TOTAL: � 40638.129 <br /> U X A= 812.76257 <br /> 3310EC3 Page 3 <br />