My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2106 EVERETT AVE 2016-01-01 MF Import
>
Address Records
>
EVERETT AVE
>
2106
>
2106 EVERETT AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2017 7:33:56 PM
Creation date
2/12/2017 7:33:04 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
2106
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> . <br /> 2�o � �-r.�a-�.c_-t/ �f�,�c� <br /> � 16. Ezlerior (court) walis within .................... feet of ' 31. Wood strippin� or suspendeA wood systems tor <br /> lines shc:�ld be of...............:hour constructioa gypsum board r.eilin�s should be not less than <br /> Section .................... 03 (a). 2•inch nominal ttiickness. Section 4704 (b). . <br /> � '� ]7. Openings in ezterior (court) walls within ..,......... [Section 4703 (b) for wall strippin�J <br /> feet of property lines should be protected with � 32. Final partilion layouts and details should be sub- <br /> thmo-faurths�hour Tire assembiies. Section � mitted prior to installation to juslify compli• <br /> � .................... 03 (b). ance with occupancy, firo-resislivc, structurat, <br /> '' 16. Usable space under the first floor ezcept in and exit requirements. <br /> Group I (J) Occupancies should be enclosed �' 33. Justitying test data in conformance with Section <br /> as required in Section 1703. 106 or an IC�O research recommendation is <br /> " 19. Firo-resistive construction for structural frame required for....................................................... <br /> elements in tlic exterior walls should comply 34. Rooms in which rubbish (linen) chWes terminale <br /> . with Footnotc No. 1 0( Table No. 17-A and should be separaled �rom tlie remainder of the <br /> Sedion ......................... See Section 1702 for building witli a one•hour occupancy separation. <br /> clarifiwtion. - Section 1706 (c). <br /> '' 20. Buildin� paper should be applied to exterior " 35. Openings into rubbish and linen chutes should <br /> walls as speci(ied in Section 1707 (a). not be located in required exit corridors or <br /> � 21. Enr.losures for floor openings should campiy stairways. SeUion 170G (c). <br /> witli Tablc No. 17�A, Section 1706. Details <br /> sliouid clearly indicate this. SPECIAL OCCUPANCY REQUIREMENTS <br /> 22. Slructural members carryiny masonry or con� .......................................................................... <br /> crete walls in buildin�;s over one story in height ................._:...................................................... <br /> should be protected with minimum one•hour ' <br /> li�e prolection. Section 1705. Group B <br /> .......................................................................... <br /> . .......................................................................... '" 36. B•3 Occ�pancies shoulA 6e of one�liour tire• <br /> ' •������•������............................................................ resistive construction if Iocated in a ba:ement <br /> or abovathe tirst story. Section 702 (b). <br /> 23. Nonabsorbent finisii and backing tor toilel room ' - <br /> walis and tloor should conform with Section " 37. 0•2 Occupancies with an occupant load of 1000 <br /> 1711 (a), or more sliould be in Type I, II, III onnhour, III . <br /> , Heavy Timbcr or IV one�hour buildings. The <br /> - 24. Shower stall walls should be linished with a assembly room should not be in a 6asement <br /> hard, nonabsorbent SuAace to a hei�ht of 6 if it contains lhis hi�h occupant ioad. Section <br /> feeL Section llli (b). " 702 (hl. <br /> � " 25. Doors and paneis of shower and ba(htub en � 3II.� The main entrance shovid front AirecUy upon or <br /> closure should comply wi(h Sedion 17ll (e) have a 20�foot wide access to a puhlic way at <br /> �o (C)• least 20 feet in width. Section 703. <br /> " 26. Parapet wails not less than ................ inches in 39. Light and ventilation should comply with Section <br /> - heigirt am required. Section 1709. 705. <br /> . '" 27. Eave overhan�s and similar architectural pro� ° �0. A Ono-Hour Fire•Resistive Occupancy Separation � <br /> jections should comply with Section 1710. is required between lhe boiler or central heat• <br /> .......................................................................... i�g plant and thc rest of tlie building. Section <br /> , '......................................................................... . � <br /> 708. <br /> ✓ 41. Ezlerior openinEs tor rooms containinG a boiler <br /> 28. Projeclions beyond lhe exlerior wall should con- or tenlral heatin� plan[ shouid be prolected <br /> fonn wilh the Icast restrictive of thc follo�vinG: with thrce�lourths�hour fire�resistivc assmnblies <br /> (a) A point one�third the distance lo the proper� tliat are fized, autoinatic, or self-closin� i( lo� <br /> , ty Iine from an exierior wall, Seclion 504 cated below openin�;s in another slory or if less <br /> ����' ihan 10 (eel from aUmr doors or windows in <br /> (b) A paint onedhirA the distance from an as- lhe same building. Seclion 706. <br /> sumed veilical nlane located where fire� <br /> resislive prolcttlon of openings is first re• GroupC � <br /> . quired due to bcalion of propertyt Seclion <br /> SO4 (b). <br /> 42, hlntaspheric separations shouid comply with <br /> ................................. ........................... . Seclion 802 (b). <br /> ..................................................... <br /> � .................... <br /> ' 43. Usc of rooms should bc clarificd. Notc that <br /> 29. Envelope ceilin�s shoWd satis(y Ihe (ollowin� rooms in Divisions 1 and 2 Occnp�nCies U=ed <br /> conditions LSection 43C'9 (b) G.1• for day care purposes and rooms used for <br /> '�(a) Should not be used to pravidc tire proLec kindcr�arten, lirsl, or second grade pupils and <br /> tion beam and girders supporting mom than Uivision 3 Uceupancics eannol be located <br /> one Iloor. abovc ihc lirsl s(ory. Scclion 802 (c). <br /> (b) Columns should be individualiy firc pro� - <br /> tected. � 4q. Special hazard rooms siiou�A he separated trom <br /> (c) Dur.t and outlet openin�s are limiled lo ]00 olhcr porlions of Ihe buiiding by not Iess ihan <br /> square inches in wch 100 square feet a( a OnrHour fim�Resistive OcCupancy separa• <br /> ceilin� area and should be prolected wilh lion. Section II02 (d), <br /> d approved fim dampeis, q�, O��c required exit should front direcUy upon, or <br /> O [Iectricai outlM hores shoulA be of sleJ have n 20400t wide access to, a pu6lic way a( <br /> • nnd not �realer than 1G square inches In Ieas( 20 feel in width. Section k303 (a). <br /> .rea. <br /> ' 30. Gypsum board ceilings in conjunction with firo- QG. Sanitary facitilics should bc p�ovidc:l in accmd• <br /> resi;tive 155CO1bIiC5 slimild be supporiM at ancr. witli Seclion E05. <br /> inlervals nol exceedin� 7G inches. Ilem 27, A7. Liehl and ��mriilalion ,hould comply with Section <br /> Table No. 43�C. a�� <br /> Shcet No. 2 of G Shcets <br />
The URL can be used to link to this page
Your browser does not support the video tag.