Laserfiche WebLink
rc aasss� <br /> August 10, 1995 <br /> Page 2 ' <br /> 4. Foundadon plates or sills shall be bolted to the foundation or foundation wall <br /> with not less than 1/2' nominal diameter steel bolts embedded at least 7 inches <br /> into the concrete and spaced not more than 72 inches apart. There shall be a <br /> minimum of 2 bolu per piece with one bolt located within 12 inches or each end <br /> of each piece. A properly sized nut and washer shall be tightened on each bolt <br /> to the plate. <br /> In order for the processing of your applicatio.� to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of drawings reflecting the <br /> corrections requested. <br /> Upon resubmittal of the drawings, your application will be given priority and plan <br /> review will recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient informadon to <br /> ensure that the proposed structure will be constructed in compliance with all adopted <br /> codes. <br /> Sincerely, <br /> ���`� �' ���-- <br /> Jeff Heilman <br /> Development Technician <br /> 1H:jd:48857 <br />