My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2019 8:19:18 AM
Creation date
2/13/2017 6:55:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JOHN D. GFilFFIN ASSOCIATES <br /> Consulting Engineer/Structural-Civil <br /> 11680 SLATER AVENUE N.E. KIRKLAND,WASHINGTON 98033 823-990;, <br /> C � I.t!1fJl:; �„O ��� ._ l;li- ' 1 �CG:C� 'tl(:7�,_I UI1 l li i:l'.P. i.'�� 1 t;f1llU�lGJ�!. <br /> t�) Gr�ade 40 reintorcii�;�; ic ��;ccif'ied. Aspli�lr,;c i;c�Y,cr E�roof- <br /> ing added to 1/sl . <br /> Con:s;ent �i. 2) Compl,�. <br /> b) Comply. <br /> c) Colu�nn� are :in sin�;1�� bendi���r t:itih t:h2 r;inui.uw b�r�dinr <br /> u:omenL occurring at Y,ne top of tl�e footin�. Provide <br /> splice at the base of the footing to develop the reinforc- <br /> �nf;. <br /> d) 7'ic:; are not required for footing reinforcement per 2607;1) . <br /> Tliis section specifically refers to"beams" and is intended <br /> to provide confinement for compression reinforcement or <br /> Lension reinforcement that goes into compression durin�r a <br /> rcversal o£ stresses at the joint. ;he ACI camnentiarti� on <br /> LP�is section is very clear as t� the intent of the re- <br /> auirement and it does not 2pplies .in this casc. <br /> ��) E3�.,e supplemental calculation sheet. <br /> f) See supplemental calculation shect. <br /> g) Uplift forces in the columns due tio overturning do noi: <br /> �overn the design of the footings for this project. Por <br /> �ill frames the uplift force is much less than the column <br /> dead lozd. The footing design was based on the maximum alio��- <br /> able soi] pressure includin� all gravity loads and comprrss- <br /> ion forces due to overturnin�. This condition �;ives �he <br /> e;�>:imum mcmenrs in the i'ooLin� . <br /> h) Ccmply. <br /> Ccn��t�t 5. a) Comply. <br /> b) Th�re is no s���clfic ruq��ire:nenti in ti.e code t;o ]�-;ve a cirdor <br /> f��3rning into a coliunn in each per�pendicular direction as <br /> inaicated in this comment. There is a requirement that i,,:� <br /> f'rame members be laterally supported which is met in thie; <br /> instance b}- the deck and slab diaphragm of the flooi� system. <br /> Ylease see the Commentary on the ��Recommended Lateral <br /> Force Requirements", Seismolo�� Committee, Structurai <br /> Gngineers Association of California regarding the deFinit- <br /> ion of a Space Frame. <br /> c) The detail as used is standard pract=ce for Ductile Moment <br /> Resisting Space i' ames. The philosophy of the connection <br /> designs shovm is as �iven in the "Reco�runended Lateral For•ce <br /> fiequirements" of SEAOC. This philosophy is that the f'lan�e:s <br /> are iaelded to transfer the moment, and the icsultinr* shesr <br />
The URL can be used to link to this page
Your browser does not support the video tag.