Flan Check 17�2 <br /> Larry Callahan <br /> September 10, 1905 <br /> Page 7'wo <br /> 4. g. Design of fooings in ductile frames: The bending moments at the base <br /> of the columns, which are transmitted by the footings to the soil, are <br /> approximately equal for the full liv� load case and the no live load case. <br /> However, the moment arm (e) on the footing (i.e. e = M/P) increases <br /> for the de�d lod only condition and should be considered when calcu- <br /> lating tlie soil pressure. <br /> 5. b. Beam-column joints which ai e not within (and parallel to) the ductile <br /> frames: When only portions of the structural frame are ductile, P.20-C <br /> of the S�AOC Commentary stipuiates: "The larger displacements. . . <br /> (of ductile frames) must not jeopardize the vertical load capabilities of <br /> all oiiier load ca;ryiny elemen[s not part of tlie seismic 'resisting systern." <br /> O��r recommendation for a framin� member placed in both directions at <br /> every column is based on this. It ultimately shoulci be left to the dis- <br /> cretion of the engineer, but taking into account the SEAOC requir•ement. <br /> c. Beam-to-column con�ections in ductile frames: Mr. Griffir has referenced <br /> P.81-C of the SEAOC Commentary for desiyn of the conneciions. Note <br /> that P.87-C st�tes "a full penetration welded web connection. . .would <br /> develop somewhat greater ductility than the bolted web." UBC Section <br /> 2722(d) is more specific: '4�ach beam or girder moment connection to a <br /> column shall be capable of dee2loping in the beam the full plastic capa- <br /> city of the beam or girder" unless "it can be shown that adequtely duc- <br /> tile joint displacement capacity is provided with a lesser connection." <br /> The connection as detailed does not deve!op the plastic moment czpacity <br /> of the beam f�.e. area of flange times beam depth is only about 2/3 of <br /> the plastic section modulus) . The connection detail, therefore, requires <br /> justification to demonstrate that adequaYe ductile joint displacement is <br /> provided. <br /> d. Adequacyof doubler plates: The designer hz- indicated 50 Icsi stee;. <br /> The note at the bottom of the doubler plate schedule states "plates a�c <br /> ASTht A36 at columns." Some clarification of the drawings appears ap- <br /> propriate. <br /> 6. b. The details of the suspended ceiling will have to �e much more speci- <br /> ' fic to really assure :hat a 2 hour floor/ceiling assembly is achieved. <br /> Refer to Evaluation Report PFC 2896 and Architectural Section d/A-9. <br /> 7. c. Test data and yuality-control program for "Tat`trus" girders: For your <br /> information. <br /> 10. b,e,f. Design of skylights, canopies, suspended ceilings, curtain walls, <br /> etc. by manufacturer for wind pressures and lateral deflections: <br /> These should be submitted to }'ou prior to fabrication ior review. <br /> � . <br />