Laserfiche WebLink
1327.13— 1328.4 UNIFORM PLUMBING CODE <br /> mrJic�l �acuum s�strms, a crrli(icalr of appro��al 1328.2.6 Punclional teslin� of all sources of <br /> sh.ill bc issucd by lhr :\ulhurity I la��in};Jurisdiction suppl�'. <br /> lo thc pennittec. 1328.2.7 Pwiction�l testing o( alarm systems. <br /> 1327.14 Covering or Use. Nn medical gas�» medical induding accuracy o(s}'slem componrnls. <br /> vacuum s}'stem or part thereo( shall be covered, 1328.2.8 Purge Flushing af system and filling <br /> concealed, or put into use until it has been tested, with specific source gases. <br /> inspecled,and acmpled as rcquired in this code. 1328.2.9 Tesling for puritt� and deanliness o( <br /> 1327.15 Uncovering. Any medical gas and aaawm source gases. <br /> system or part thereof that is co��ered or concealed 1328.2.10 Testing for specific gas identity at each <br /> beforc testing nnd inspecicd as requircd in this mde station oullel. <br /> shall bc uncovcred (ur inspeclion, aftcr noticc to 1328.3 Thc inspeclion and testing rcports shall bc <br /> uncover the�rork hns been issued lo the permittee or submilled direcUc to the parlv Ihat cuntracted for the <br /> his authorired mprescnlative by Uie Authority lcsting, t��ho shall submit lhc report through channcls <br /> Having Jurisdiction. to thc respoitcible fadlil�� authoritv and an}�ethers that <br /> are mquired.[NPPA 99 5.1.12.1.G�. <br /> 1328.0 System Certification. Reports shall ronWin detailed listings of all <br /> 1328.1 Prior to anp medic�il gas s}'slem Ueing placed findings and resulls. �NI�1'A 99 5.1.12.1.7] <br /> in ser�•ice, each and e��rrJ• s�•slem shall be certified, 1328.4 A report that includes al Ieast die spccific <br /> ,udrscribrd inSeclion ]32K.2. items mentiunrd in Section lJ2S.2 and aIl other <br /> 1328.1.1 Verificalion tesls �hall bc per(urmeJ inlormation myuired bt� NPI'A �)9 Stundard fi�r Flralth <br /> nnl�• aNer all tests myuired in ticction 1327.0, G�n• Fnrilitirs shall br drlivcred lu lhe Authorih• <br /> InslallerPedormed 'fest,, ha�e been iompieted. Having Jurisdiction priur to acceptanm of the s�•slem. <br /> (N PPA 99 S.l.l?.3.I J� <br /> I'cslin}; sh�ll bc conducted b.: a part�• <br /> irchnically rumpctcnt and rspericncrd in Ihc <br /> lirld o(nuJical ga.nnd �acuum pipelinr testing <br /> and mcclin� lhc rcyuircmrnls of �W51/ASSG <br /> Slandard b0:�0, Al��diral G�is l'rrifitr. Pro�as:ionnl <br /> �ualirirations tihaidnrJ. �NI�PA 995.1.12.3.1.3� <br /> I'csting shall l�c �,crformrd t��� a porh• ��t6rr <br /> lhan lhr inslallinp, contraclor. �NPI':\ ",� <br /> �.I.I'_.3.I.d� <br /> 1\'lirn s�'stems ha�•e becn installed L�c in- <br /> housc prrsonncl, tcstinp, sh�ill bc pennitt���f bc <br /> �,rrsonncl of that or};anization �aho mrrl Ihr <br /> rcyuiremenls ut this ,ecliun. �Nrl':\ '"� <br /> 5.1.12.3.1.5� <br /> 1328.2 Cerlilicalion trsls, ��erificd and ;iltestrd t�, I�c <br /> the mrlificalion agrncy,shall indudc thc (ullon ini; <br /> 1328.2.1 Vcrif�'in�; compliancc ��•ilh �hr <br /> installation rcquircmenls. <br /> 1328.2.2 Testing and checking for le�kagr, <br /> tc,rrect r.oning, and idrntification of contml <br /> �•olt�cs. <br /> 1328.2.3 Checking for identificalion ,in�l <br /> labrling of pipclinrs, stalion ouUcls, +md contn�l <br /> ��ah•es. <br /> 1328.2.4 Testing Eur a'oss-conncctiun, flo�c r.�lr. <br /> ��.Icm pres.urc dmp,and syslcm prrforman�r. <br /> 1328.2.5 Punctii�nnl tcs�in}; of �,rc�surc rrli�d <br /> �al��r,,m�i �,ifrtc c,il��r.. <br /> 218 � <br />